欢迎访问ic37.com |
会员登录 免费注册
发布采购

16760A 参数 Datasheet PDF下载

16760A图片预览
型号: 16760A
PDF下载: 下载PDF文件 查看货源
内容描述: 逻辑分析仪 [Logic Analyzer]
分类和应用:
文件页数/大小: 35 页 / 1054 K
品牌: AGILENT [ AGILENT TECHNOLOGIES, LTD. ]
 浏览型号16760A的Datasheet PDF文件第14页浏览型号16760A的Datasheet PDF文件第15页浏览型号16760A的Datasheet PDF文件第16页浏览型号16760A的Datasheet PDF文件第17页浏览型号16760A的Datasheet PDF文件第19页浏览型号16760A的Datasheet PDF文件第20页浏览型号16760A的Datasheet PDF文件第21页浏览型号16760A的Datasheet PDF文件第22页  
Agilent 16760A Specifications and Characteristics  
Agilent Technologies 16760A Supplemental Specifications* and Characteristics (continued)  
Synchronous Data Sampling  
User Adjustable Settings for Each Input  
Parameter  
Adjustment Range  
1500 Mb/s mode 1250 Mb/s mode 800 Mb/s mode  
400 Mb/s mode  
200 Mb/s mode  
Data  
Adjustment Resolution 10 ps  
10 ps  
10 ps  
100 ps  
100 ps  
to Clock  
tSample [5]  
0 to ꢀ4 ns  
–2.5 to ꢀ2.5 ns  
–2.5 to ꢀ2.5 ns  
–3.2 to ꢀ3.2 ns  
–3.5 to ꢀ3 ns  
All  
Inputs  
vThreshold [6]  
10 mV resolution 10 mV resolution 10 mV resolution 10 mV resolution 10 mV resolution  
–3 to ꢀ5 V –3 to ꢀ5 V –3 to ꢀ5 V –3 to ꢀ5 V –3 to ꢀ5 V  
*
All specifications noted by an asterisk in the table are the performance standards against which the product is tested.  
[1] The analyzer can be configured to sample on the rising edge, the falling edge, or both edges of the clock. If both edges are used with a single ended clock input, take care to set  
the clock threshold accurately to avoid phase error.  
[2] Eye width and height are specified at the probe tip. Eye width as measured by eye finder in the analyzer may be less, and still sample reliably.  
[3] For each side of a differential signal.  
[4] The clock inputs in the E5378A, E5398A, E5406A, E5390A, and E5382A may be connected differentially or single ended. Use the E5379A vHeight spec for clock channel(s)  
connected differentially.  
[5] Sample positions are independently adjustable for each data channel input. A negative sample position causes the input to be synchronously sampled by that amount before  
each active clock edge. A positive sample position causes the input to be synchronously sampled by that amount after each active clock edge. A sampling position of zero  
causes synchronous sampling coincident with each active clock edge.  
[6] Threshold applies to single-ended input signals. Thresholds are independently adjustable for the clock input of each pod and for each set of 16 data inputs for each pod.  
Threshold limits apply to both the internal reference and to the external reference input on the E5378A.  
vHeight  
pSignal  
——0V—— 2X vHeight  
S
vHeight  
nSignal  
18  
 复制成功!