ADM9240  
FAN MANUFACTURERS  
Manufacturers of cooling fans with tachometer outputs are  
listed below:  
T o accommodate fans of different speed and/or different num-  
bers of output pulses per revolution, a prescaler (divisor) of 1, 2,  
4 or 8 may be added before the counter. T he default value is 2,  
which gives a count of 153 for a fan running at 4400 rpm pro-  
ducing two output pulses per revolution.  
NMB T ech  
9730 Independence Ave.  
Chatsworth, California 91311  
818-341-3355  
T he count is calculated by the equation:  
Count = (22.5 × 103 × 60) /(rpm × Divisor)  
818-341-8207  
For constant speed fans, fan failure is normally considered to  
have occurred when the speed drops below 70% of nominal,  
which would correspond to a count of 219. Full scale (255)  
would be reached if the fan speed fell to 60% of its nominal  
value. For temperature controlled variable speed fans the situa-  
tion will be different.  
Airflow  
CFM  
Model  
Fram e Size  
2408NL 2.36 in sq. × 0.79 in (60 mm sq. × 20 mm) 9–16  
2410ML 2.36 in sq. × 0.98 in (60 mm sq. × 25 mm) 14–25  
3108NL 3.15 in sq. × 0.79 in (80 mm sq. × 20 mm) 25–42  
3110KL 3.15 in sq. × 0.98 in (80 mm sq. × 25 mm) 25–40  
T able III shows the relationship between fan speed and time per  
revolution at 60%, 70% and 100% of nominal rpm for fan  
speeds of 1100 rpm, 2200 rpm, 4400 rpm and 8800 rpm, and  
the divisor that would be used for each of these fans, based on  
two tacho pulses per revolution.  
Mechatronis Inc.  
P.O. Box 613  
Preston, WA 98050  
800-453-4569  
Models—Various sizes available with tach output option.  
Table III. Fan Speeds and D ivisors  
Sanyo Denki/Keymarc Electronics  
468 Amapola Ave.  
T orrance, CA 90501  
310-783-5400  
Tim e per  
70% Rev  
Tim e per  
60% Rev  
Tim e per  
60% Rev  
(m s)  
Nom inal  
r pm  
D ivisor  
(m s)  
r pm  
(m s)  
r pm  
Models—109P Series  
1
2
4
8
8800  
4400  
2200  
1100  
6.82  
6160  
3080  
1540  
770  
9.74  
5280  
2640  
1320  
660  
11.36  
22.73  
45.45  
90.9  
13.64  
27.27  
54.54  
19.48  
38.96  
77.92  
CH ASSIS INTRUSIO N INP UT  
T he Chassis Intrusion (CI) input is an active high input/open-  
drain output intended for detection and signalling of unautho-  
rized tampering with the system. An external circuit powered  
from the system’s CMOS backup battery is used to detect and  
latch a chassis intrusion event, whether the system is powered up  
or not. Once a chassis intrusion has been detected and latched,  
the CI input will generate an interrupt when the system is pow-  
ered up.  
Note that Fan 1 and Fan 2 Divisors are programmed into Bits 4  
to 7 of the VID0–VID3/Fan Divisor Register.  
LIMIT VALUES  
Fans in general will not overspeed if run from the correct volt-  
age, so the failure condition of interest is underspeed due to  
electrical or mechanical failure. For this reason only low speed  
limits are programmed into the limit registers for the fans. It  
should be noted that, since fan period rather than speed is being  
measured, a fan failure interrupt will occur when the measure-  
ment exceeds the limit value.  
T he actual detection of chassis intrusion is performed by an  
external circuit that will, for example, detect when the cover has  
been removed. A wide variety of techniques may be used for the  
detection:  
Microswitch that opens or closes when the cover is removed.  
– Reed switch operated by magnet fixed to the cover.  
Hall-effect switch operated by magnet fixed to the cover.  
– Phototransistor that detects light when cover is removed.  
MO NITO RING CYCLE TIME  
T he monitoring cycle time depends on the fan speed and num-  
ber of tacho output pulses per revolution. T wo complete periods  
of the fan tacho output (three rising edges) are required for each  
fan measurement. T herefore, if the start of a fan measurement  
just misses a rising edge, the measurement can take almost three  
tacho periods. In order to read a valid result from the fan value  
registers, the total monitoring time allowed after starting the  
monitoring cycle should therefore be three tacho periods of  
FAN1 plus three tacho periods of FAN2 at the lowest normal  
fan speed.  
T he chassis intrusion interrupt will remain asserted until the  
external detection circuit is reset. T his can be achieved by set-  
ting Bit 6 of the Configuration Register, or Bit 7 of the Chassis  
Intrusion Clear Register to one, which will cause the CI pin to be  
pulled low for at least 20 ms. T hese register bits are self-clearing.  
Although the fan monitoring cycle and the analog input moni-  
toring cycle are started together, they are not synchronized in  
any other way.  
REV. 0  
–13–