ADM1026  
Table 123. Register 6Eh, Ext1 Temp Offset (Power-On Default 00h)  
Bit  
Name  
R/W  
Description  
7–0  
Ext± Temp Offset  
R/W  
This register contains the offset value for the external ± temperature channel. A twos complement  
number can be written to this register, which is then added to the measured result before it is  
stored or compared to limits. In this way, a sort of one-point calibration can be done whereby the  
whole transfer function of the channel can be moved up or down. From a software point of view,  
this may be a very simple method to vary the characteristics of the measurement channel if the  
thermal characteristics change for any reason (for instance from one chassis to another), if the  
measurement point is moved, if a plug-in card is inserted or removed, and so on.  
Table 124. Register 6Fh, Ext2 Temp Offset (Power-On Default 00h)  
Bit  
Name  
R/W  
Description  
7–0  
Ext2 Temp Offset  
R/W  
This register contains the offset value for the external 2 temperature channel. A twos complement  
number can be written to this register, which is then added to the measured result before it is  
stored or compared to limits. In this way, a sort of one-point calibration can be done whereby the  
whole transfer function of the channel can be moved up or down. From a software point of view,  
this may be a very simple method to vary the characteristics of the measurement channel if the  
thermal characteristics change for any reason (for instance from one chassis to another), if the  
measurement point is moved, if a plug-in card is inserted or removed, and so on.  
Rev. A | Page 53 of 56  