ADF4360-3  
Data Sheet  
Charge Pump Currents  
CONTROL LATCH  
CPI3, CPI2, and CPI1 in the ADF4360 family determine  
Current Setting 1.  
With (C2, C1) = (0, 0), the control latch is programmed. Table 7  
shows the input data format for programming the control latch.  
CPI6, CPI5, and CPI4 determine Current Setting 2. See the  
truth table in Table 7.  
Prescaler Value  
In the ADF4360 family, P2 and P1 in the control latch set the  
prescaler values.  
Output Power Level  
Bits PL1 and PL2 set the output power level of the VCO. See the  
truth table in Table 7.  
Power-Down  
DB21 (PD2) and DB20 (PD1) provide programmable pow-  
erdown modes.  
Mute-Till-Lock Detect  
DB11 of the control latch in the ADF4360 family is the mute-till-  
lock detect bit. This function, when enabled, ensures that the RF  
outputs are not switched on until the PLL is locked.  
In the programmed asynchronous power-down, the device  
powers down immediately after latching a 1 into Bit PD1, with  
the condition that PD2 has been loaded with a 0. In the pro-  
grammed synchronous power-down, the device power-down is  
gated by the charge pump to prevent unwanted frequency  
jumps. Once the power-down is enabled by writing a 1 into  
Bit PD1 (on the condition that a 1 has also been loaded to PD2),  
the device will go into power-down on the second rising edge of  
the R counter output, after LE goes high. When the CE pin is  
low, the device is immediately disabled regardless of the state of  
PD1 or PD2.  
CP Gain  
DB10 of the control latch in the ADF4360 family is the charge  
pump gain bit. When it is programmed to a 1, Current Setting 2  
is used. When it is programmed to a 0, Current Setting 1 is  
used.  
Charge Pump Three-State  
This bit puts the charge pump into three-state mode when  
programmed to a 1. It should be set to 0 for normal operation.  
When a power-down is activated (either synchronous or  
asynchronous mode), the following events occur:  
Phase Detector Polarity  
The PDP bit in the ADF4360 family sets the phase detector  
polarity. The positive setting enabled by programming a 1 is  
used when using the on-chip VCO with a passive loop filter or  
with an active noninverting filter. It can also be set to 0. This is  
required if an active inverting loop filter is used.  
All active dc current paths are removed.  
The R, N, and timeout counters are forced to their load  
state conditions.  
MUXOUT Control  
The charge pump is forced into three-state mode.  
The digital lock detect circuitry is reset.  
The on-chip multiplexer is controlled by M3, M2, and M1.  
See the truth table in Table 7.  
The RF outputs are debiased to a high impedance state.  
The reference input buffer circuitry is disabled.  
Counter Reset  
DB4 is the counter reset bit for the ADF4360 family. When this  
is 1, the R counter and the A, B counters are reset. For normal  
operation, this bit should be 0.  
The input register remains active and capable of loading and  
latching data.  
Core Power Level  
PC1 and PC2 set the power level in the VCO core. The recom-  
mended setting is 15 mA. See the truth table in Table 7.  
Rev. C | Page 18 of 24  
 