 浏览型号ADF4113BRU-REEL的Datasheet PDF文件第16页浏览型号ADF4113BRU-REEL的Datasheet PDF文件第17页浏览型号ADF4113BRU-REEL的Datasheet PDF文件第18页浏览型号ADF4113BRU-REEL的Datasheet PDF文件第19页浏览型号ADF4113BRU-REEL的Datasheet PDF文件第21页浏览型号ADF4113BRU-REEL的Datasheet PDF文件第22页浏览型号ADF4113BRU-REEL的Datasheet PDF文件第23页浏览型号ADF4113BRU-REEL的Datasheet PDF文件第24页  
ADF4110/ADF4111/ADF4112/ADF4113  
Note that there is an enable feature on the timer counter. It is  
enabled when Fastlock Mode 2 is chosen by setting the fastlock  
mode bit (DB10) in the function latch to 1.  
When the initialization latch is loaded, the following occurs:  
1. The function latch contents are loaded.  
Charge Pump Currents  
2. An internal pulse resets the R, A, B, and timeout counters  
to load state conditions and three-states the charge pump.  
Note that the prescaler band gap reference and the oscil-  
lator input buffer are unaffected by the internal reset pulse,  
allowing close phase alignment when counting resumes.  
CPI3, CPI2, and CPI1 program Current Setting 1 for the charge  
pump. CPI6, CPI5, and CPI4 program Current Setting 2 for the  
charge pump. The truth table is given in Table 10.  
Prescaler Value  
3. Latching the first AB counter data after the initialization  
word activates the same internal reset pulse. Successive AB  
loads do not trigger the internal reset pulse unless there is  
another initialization.  
P2 and P1 in the function latch set the prescaler values. The  
prescaler value should be chosen so that the prescaler output  
frequency is always less than or equal to 200 MHz. Thus, with  
an RF frequency of 2 GHz, a prescaler value of 16/17 is valid but  
a value of 8/9 is not.  
CE Pin Method  
PD Polarity  
1. Apply VDD  
.
This bit sets the phase detector polarity bit. See Table 10.  
2. Bring CE low to put the device into power-down. This is an  
asynchronous power-down in that it happens immediately.  
CP Three-State  
This bit controls the CP output pin. With the bit set high, the CP  
output is put into three-state. With the bit set low, the CP output  
is enabled.  
3. Program the function latch (10). Program the R counter  
latch (00). Program the AB counter latch (01).  
4. Bring CE high to take the device out of power-down. The R  
and AB counters now resume counting in close alignment.  
INITIALIZATION LATCH  
When C2, C1 = 1, 1, the initialization latch is programmed. This  
is essentially the same as the function latch (programmed when  
C2, C1 = 1, 0).  
After CE goes high, a duration of 1 µs may be required for the  
prescaler band gap voltage and oscillator input buffer bias to  
reach steady state.  
However, when the initialization latch is programmed, an addi-  
tional internal reset pulse is applied to the R and AB counters.  
This pulse ensures that the AB counter is at load point when the  
AB counter data is latched, and the device begins counting in  
close phase alignment.  
CE can be used to power the device up and down in order to  
check for channel activity. The input register does not need to  
be reprogrammed each time the device is disabled and enabled  
as long as it has been programmed at least once after VDD was  
initially applied.  
If the latch is programmed for synchronous power-down (CE  
pin high% PD1 bit high% PD2 bit low), the internal pulse also  
triggers this power-down. The prescaler reference and the  
oscillator input buffer are unaffected by the internal reset pulse,  
so close phase alignment is maintained when counting resumes.  
Counter Reset Method  
1. Apply VDD  
.
2. Do a function latch load (10 in 2 LSBs). As part of this, load  
1 to the F1 bit. This enables the counter reset.  
When the first AB counter data is latched after initialization, the  
internal reset pulse is again activated. However, successive AB  
counter loads after this will not trigger the internal reset pulse.  
3. Do an R counter load (00 in 2 LSBs). Do an AB counter  
load (01 in 2 LSBs). Do a function latch load (10 in 2 LSBs).  
As part of this, load 0 to the F1 bit. This disables the  
counter reset.  
DEVICE PROGRAMMING AFTER INITIAL  
POWER-UP  
This sequence provides the same close alignment as the initiali-  
zation method. It offers direct control over the internal reset.  
Note that counter reset holds the counters at load point and  
three states the charge pump but does not trigger synchronous  
power-down. The counter reset method requires an extra  
function latch load compared to the initialization latch method.  
After initial power-up of the device, there are three ways to  
program the device.  
Initialization Latch Method  
Apply VDD. Program the initialization latch (11 in 2 LSBs of  
input word). Make sure the F1 bit is programmed to 0. Then, do  
an R load (00 in 2 LSBs). Then do an AB load (01 in 2 LSBs).  
Rev. C | Page 20 of 28  
 