 浏览型号AD9850BRSZ-REEL的Datasheet PDF文件第5页浏览型号AD9850BRSZ-REEL的Datasheet PDF文件第6页浏览型号AD9850BRSZ-REEL的Datasheet PDF文件第7页浏览型号AD9850BRSZ-REEL的Datasheet PDF文件第8页浏览型号AD9850BRSZ-REEL的Datasheet PDF文件第10页浏览型号AD9850BRSZ-REEL的Datasheet PDF文件第11页浏览型号AD9850BRSZ-REEL的Datasheet PDF文件第12页浏览型号AD9850BRSZ-REEL的Datasheet PDF文件第13页  
AD9850  
REF  
CLOCK  
DDS CIRCUITRY  
AMPLITUDE/COS  
CONV.  
ALGORITHM  
N
PHASE  
ACCUMULATOR  
D/A  
CONVERTER  
CLK  
OUT  
LP  
COMPARATOR  
TUNING WORD SPECIFIES  
OUTPUT FREQUENCY  
AS A FRACTION OF REF  
CLOCK FREQUENCY  
COS (x)  
IN DIGITAL DOMAIN  
Figure 4. Basic DDS Block Diagram and Signal Flow of AD9850  
and automatically places itself in the power-down mode. When  
in this state, if the clock frequency again exceeds the threshold,  
the device resumes normal operation. This shutdown mode  
prevents excessive current leakage in the dynamic registers of  
the device.  
AD9850 is a sampled signal, its output spectrum follows the  
Nyquist sampling theorem. Specifically, its output spectrum  
contains the fundamental plus aliased signals (images) that  
occur at multiples of the reference clock frequency the  
selected output frequency. A graphical representation of the  
sampled spectrum, with aliased images, is shown in Figure 5.  
The D/A converter output and comparator inputs are available  
as differential signals that can be flexibly configured in any  
manner desired to achieve the objectives of the end system. The  
typical application of the AD9850 is with single-ended output/  
input analog signals, a single low-pass filter, and the generation  
of the comparator reference midpoint from the differential DAC  
output as shown in Figure 1.  
f
OUT  
sin(x)/x ENVELOPE  
fc – fo  
x=()fo/fc  
fc + fo  
2fc – fo  
fc  
2fc + fo  
3fc – fo  
Programming the AD9850  
The AD9850 contains a 40-bit register that is used to program the  
32-bit frequency control word, the 5-bit phase modulation word,  
and the power-down function. This register can be loaded in a  
parallel or serial mode.  
120MHz  
180MHz  
3RD IMAGE  
220MHz  
4TH IMAGE  
280MHz  
5TH IMAGE  
20MHz  
80MHz  
2ND IMAGE  
FUNDAMENTAL 1ST IMAGE  
100MHz  
REFERENCE CLOCK  
FREQUENCY  
In the parallel load mode, the register is loaded via an 8-bit bus;  
the full 40-bit word requires five iterations of the 8-bit word.  
The W_CLK and FQ_UD signals are used to address and load  
the registers. The rising edge of FQ_UD loads the (up to) 40-bit  
control data-word into the device and resets the address pointer  
to the first register. Subsequent W_CLK rising edges load the  
8-bit data on words [7:0] and move the pointer to the next  
register. After five loads, W_CLK edges are ignored until either  
a reset or an FQ_UD rising edge resets the address pointer to  
the first register.  
Figure 5. Output Spectrum of a Sampled Signal  
In this example, the reference clock is 100 MHz and the output  
frequency is set to 20 MHz. As can be seen, the aliased images  
are very prominent and of a relatively high energy level as deter-  
mined by the sin(x)/x roll-off of the quantized D/A converter  
output. In fact, depending on the fo/reference clock relation-  
ship, the first aliased image can be on the order of –3 dB below  
the fundamental. A low-pass filter is generally placed between  
the output of the D/A converter and the input of the com-  
parator to further suppress the effects of aliased images. Obvi-  
ously, consideration must be given to the relationship of the  
selected output frequency and the reference clock frequency  
to avoid unwanted (and unexpected) output anomalies.  
In serial load mode, subsequent rising edges of W_CLK shift  
the 1-bit data on Pin 25 (D7) through the 40 bits of program-  
ming information. After 40 bits are shifted through, an FQ_UD  
pulse is required to update the output frequency (or phase).  
The function assignments of the data and control words are  
shown in Table III; the detailed timing sequence for updating  
the output frequency and/or phase, resetting the device, and  
powering up/down, are shown in the timing diagrams of  
Figures 6 through 12.  
To apply the AD9850 as a clock generator, limit the selected  
output frequency to <33% of reference clock frequency, and  
thereby avoid generating aliased signals that fall within, or close  
to, the output band of interest (generally dc-selected output fre-  
quency). This practice eases the complexity (and cost) of the  
external filter requirement for the clock generator application.  
Note: There are specific control codes, used for factory test  
purposes, that render the AD9850 temporarily inoperable. The  
user must take deliberate precaution to avoid inputting the  
codes listed in Table II.  
The reference clock frequency of the AD9850 has a minimum  
limitation of 1 MHz. The device has internal circuitry that  
senses when the minimum clock rate threshold has been exceeded  