AD73360
SE
SCLK
SDOFS
UNDEFINED DATA
CONTROL WORD
UNDEFINED DATA
CONTROL WORD
SDO
SDIFS
SDI
Figure 15a. Interface Signal Timing for Program Mode Operation (Writing to a Register)
SE
SCLK
SDOFS
SDO
UNDEFINED DATA
READ RESULT
SDIFS
0x7FFF OR CONTROL WORD
SDI
REGISTER READ INSTRUCTION
Figure 15b. Interface Signal Timing for Program Mode Operation (Reading a Register)
SE
SCLK
SDOFS
CHANNEL 6 ADC SAMPLE WORD
SDO
CHANNEL 1 ADC SAMPLE WORD
SDIFS
CONTROL WORD
CONTROL WORD
SDI
Figure 16a. Interface Signal Timing for Mixed Mode Operation
SE
SCLK
SDOFS
SDO
CHANNEL 1 ADC SAMPLE WORD
CHANNEL 6 ADC SAMPLE WORD
SDIFS
SDI
DON'T CARE
DON'T CARE
Figure 16b. Interface Signal Timing for Data Mode Operation
–22–
REV. B