OVERALL SYSTEM TIMING REQUIREMENTS
(Full timing requirements to follow)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
µs
ONDLY=000
ONDLY=001
ONDLY=010
ONDLY=011
ONDLY=100
ONDLY=101
ONDLY=110
ONDLY=111
32.6
101
196
291
386
481
576
671
41
88
113
213
313
413
513
613
713
165
270
375
480
585
690
795
Regulator Programmable Startup Delay
Timings between turn on events
nRESET Delay Timing Programming
Range
199
398
996
µs
nRESET_AUX1 Delay Timing Program-
ming Range
1991
nRESET_AUX2 Delay Timing Program-
ming Range
57
40
882
60
µs
µs
nRESET, nRESET_AUX2 Min Delay
Timing1
Setting nRST_DLY=110
Setting nRESET_AUX2=111
nRESET Max Delay Timing1
Setting nRST_DLY=111
920
823
996
882
1080
942
µs
µs
nRESET_AUX1 Max Delay Timing1
Setting nRESET_AUX1_DLY=110