ACT5880  
Rev 2, 03-Sep-13  
REGISTER AND BIT DESCRIPTIONS CONT’D  
DEFAULT  
and  
ACCESS  
ADDRESS  
and BIT  
BLOCK  
NAME  
DESCRIPTION  
Set 0 for using the xtal oscillator; Set 1 for using the buck switch clock.  
7
6
CLKSRC  
nWKALM  
0
0
W/R  
W/R  
Set 0 for enabling alarm against time match. Register 0x3C and 0x3D  
need to be set 0x80 and 0x08 previous to setting this bit.  
5
4
3
2
1
0
7
x
x
x
x
x
x
x
0
0
0
0
0
0
x
x
x
x
x
x
x
x
Not used.  
Not used.  
Not used.  
Not used.  
Not used.  
Not used.  
Not used.  
0x9C  
Set 1 to load RTC with the data stored in all setting registers by its 0  
to 1 transition.  
6
5
RCL  
0
0
W/R  
W/R  
Set 1 for enabling RTC alarm. Register 0x3C and 0x3D need to be  
set 0x80 and 0x08 previous to setting this bit.  
RAAI  
4
3
2
1
RDAI  
RHAI  
RMAI  
RSAI  
0
0
0
0
W/R Set 1 for interrupt assertion for 1s when day count changes.  
W/R Set 1 for interrupt assertion for 1s when hours count changes.  
W/R Set 1 for interrupt assertion for 1s when minute count changes.  
W/R Set 1 for interrupt assertion for 0.5s when second count changes.  
0xA0  
RTC  
Set 1 to enable the RTC, set 0 to disable the RTC. This bit is cleared  
to 0 when the RTC power losses.  
0
RTCEN  
0
W/R  
Not used.  
Not used.  
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
x
x
x
0
0
0
0
0
0
x
x
0
0
0
0
0
0
x
x
x
Setting register for seconds. Store the seconds into this register firstly,  
then set the RCL[ ] to 1 to load the RTC.  
SETSEC[5]  
SETSEC[4]  
SETSEC[3]  
SETSEC[2]  
SETSEC[1]  
SETSEC[0]  
x
W/R  
W/R  
W/R  
W/R  
W/R  
W/R  
x
0xA4  
Not used.  
Not used.  
x
x
Setting register for minutes. Store the minutes into this register firstly,  
then set the RCL[ ] to 1 to load the RTC.  
SETMIN[5]  
SETMIN[4]  
SETMIN[3]  
SETMIN[2]  
SETMIN[1]  
SETMIN[0]  
W/R  
W/R  
W/R  
W/R  
W/R  
W/R  
0xA8  
Note:  
W/R: Write and read accessible. X is uncertain volume.  
www.active-semi.com  
Copyright © 2013 Active-Semi, Inc.  
Active-Semi ConfidentialDo Not Copy or Distribute  
ActivePMUTM and ActivePathTM are trademarks of Active-Semi.  
I2CTM is a trademark of NXP.  
- 32 -  
 复制成功!