Absolute Maximum Ratings1
Recommended Operating Conditions
Free air temperature range
Parameter
Commercial
Military
Units
Symbol
Parameter
Limits
Units
Temperature
Range1
0 to +70
–55 to +125
°C
VCC
VI
DC Supply Voltage2, 3, 4
Input Voltage
–0.5 to +7.0
–0.5 to VCC +0.5
–0.5 to VCC +0.5
±20
V
V
Power Supply
Tolerance2
±5
±10
%VCC
VO
IIO
Output Voltage
V
Notes:
I/O Source Sink
Current5
mA
1. Ambient temperature (TA) is used for commercial and
industrial; case temperature (TC) is used for military.
2. All power supplies must be in the recommended operating range.
For more information, refer to the Power-Up Design Considerations
application note at http://www.actel.com/appnotes.
TSTG
Storage Temperature
–65 to +150
°C
Notes:
1. Stresses beyond those listed under “Absolute Maximum Ratings”
may cause permanent damage to the device. Exposure to
absolute maximum rated conditions for extended periods may
affect device reliability. Devices should not be operated outside
the recommended operating conditions.
2. VPP = VCC , except during device programming.
3. VSV = VCC , except during device programming.
4.
5. Device inputs are normally high impedance and draw extremely
low current. However, when input voltage is greater than VCC
VKS = GND , except during device programming.
+
0.5V or less than GND – 0.5V, the internal protection diode will be
forward biased and can draw excessive current.
Electrical Specifications
Commercial
Military
Max.
Symbol Parameter
Test Condition
Min.
Max.
Min.
Units
1, 2
VOH
HIGH Level Output
IOH = –4 mA (CMOS)
3.7
V
V
I
OH = –6 mA (CMOS)
3.84
1, 2
VOL
VIH
VIL
LOW Level Output
HIGH Level Input
LOW Level Input
Input Leakage
IOL = +6 mA (CMOS)
TTL Inputs
0.33
VCC + 0.3
0.8
0.4
VCC + 0.3
0.8
V
2.0
–0.3
–10
–10
2.0
–0.3
–10
–10
V
TTL Inputs
V
IIN
VI = VCC or GND
VO = VCC or GND
+10
+10
µA
µA
pF
IOZ
3-state Output Leakage
I/O Capacitance3, 4
+10
+10
CIO
ICC(S)
10
10
Standby VCC Supply Current VI = VCC or GND, IO = 0 mA
ACT 1
3
2
20
20
mA
mA
ACT 2/3/1200XL/3200DX
ICC(D)
Dynamic VCC Supply Current
See the “Power Dissipation” section on page 11.
Notes:
1. Actel devices can drive and receive either CMOS or TTL signal levels. No assignment of I/Os as TTL or CMOS is required.
2. Tested one output at a time, VCC = min.
3. Not tested; for information only.
4. VOUT = 0V, f = 1 MHz
10