ACT™ 2 Family FPGAs
Operating Conditions
Absolute Maximum Ratings1
Recommended Operating Conditions
Free air temperature range
Commercia Industria
Parameter
l
l
Military Units
Symbol
Parameter
Limits
Units
Temperature
Range1
–40 to
+85
–55 to
°C
VCC
VI
DC Supply Voltage
Input Voltage
–0.5 to +7.0
–0.5 to VCC +0.5
–0.5 to VCC +0.5
20
V
V
0 to +70
+125
Power
Supply
Tolerance
VO
Output Voltage
V
5
10
10
%VCC
I/O Source/Sink
Current2
mA
IIO
Note:
1. Ambient temperature (TA) is used for commercial and
industrial; case temperature (TC) is used for military.
TSTG Storage Temperature
Notes:
–65 to +150
°C
1. Stresses beyond those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
Exposure to absolute maximum rated conditions for extended
periods may affect device reliability. Device should not be
operated outside the Recommended Operating Conditions.
2. Device inputs are normally high impedance and draw
extremely low current. However, when input voltage is greater
than VCC + 0.5 V or less than GND – 0.5 V, the internal
protection diode will be forward biased and can draw excessive
current.
Electrical Specifications
Commercial
Industrial
Military
Max.
Symbol
Parameter
Min.
Max.
Min.
Max.
Min.
Units
1
VOH
(IOH = –10 mA) 2
(IOH = –6 mA)
(IOH = –4 mA)
(IOL = 10 mA) 2
(IOL = 6 mA)
2.4
V
V
3.84
3.7
3.7
V
1
VOL
0.5
0.33
0.8
V
0.40
0.8
0.40
0.8
V
VIL
–0.3
–0.3
–0.3
V
VIH
2.0
VCC + 0.3
500
2.0
VCC + 0.3
500
2.0
VCC + 0.3
500
V
2
Input Transition Time tR, tF
CIO I/O Capacitance2, 3
Standby Current, ICC4 (typical = 1 mA)
Leakage Current5
ns
pF
mA
µA
10
10
10
2
10
20
–10
10
–10
10
–10
10
Notes:
1. Only one output tested at a time. VCC = min.
2. Not tested, for information only.
3. Includes worst-case 176 CPGA package capacitance. VOUT = 0 V, f = 1 MHz.
4. All outputs unloaded. All inputs = VCC or GND, typical ICC = 1 mA. ICC limit includes IPP and ISV during normal operation.
5. VOUT , VIN = VCC or GND.
4
v4.0