欢迎访问ic37.com |
会员登录 免费注册
发布采购

5962-9215604Q9D 参数 Datasheet PDF下载

5962-9215604Q9D图片预览
型号: 5962-9215604Q9D
PDF下载: 下载PDF文件 查看货源
内容描述: [Field Programmable Gate Array, 8000 Gates, 1232-Cell, CMOS, DIE]
分类和应用: 可编程逻辑
文件页数/大小: 34 页 / 367 K
品牌: ACTEL [ Actel Corporation ]
 浏览型号5962-9215604Q9D的Datasheet PDF文件第14页浏览型号5962-9215604Q9D的Datasheet PDF文件第15页浏览型号5962-9215604Q9D的Datasheet PDF文件第16页浏览型号5962-9215604Q9D的Datasheet PDF文件第17页浏览型号5962-9215604Q9D的Datasheet PDF文件第19页浏览型号5962-9215604Q9D的Datasheet PDF文件第20页浏览型号5962-9215604Q9D的Datasheet PDF文件第21页浏览型号5962-9215604Q9D的Datasheet PDF文件第22页  
TABLE IIA. Electrical test requirements. 1/ 2/ 3/ 4/ 5/ 6/ 7/  
Line  
no.  
Test requirements  
Subgroups  
(in accordance with  
MIL-STD-883,  
Subgroups  
(in accordance with  
MIL-PRF-38535, table III)  
TM 5005, table I)  
Device  
class M  
Device  
class Q  
Device  
class V  
1
2
Interim electrical parameters  
(see 4.2)  
1, 7, 9  
Static burn-in  
(method 1015)  
Not  
required  
Not  
required  
Required  
3
4
Same as line 1  
1*, 7* ∆  
Dynamic burn-in  
(method 1015)  
Required  
Required  
Required  
5
6
Same as line 1  
1*, 7* ∆  
Final electrical  
parameters (see 4.2)  
1*, 2, 3, 7*, 8A,  
8B, 9, 10, 11  
1*, 2, 3, 7*, 8A,  
8B, 9, 10, 11  
1*, 2, 3, 7*, 8A,  
8B, 9, 10, 11  
7
8
Group A test requirements (see  
4.4)  
1, 2, 3, 4**, 7,  
8A, 8B, 9, 10, 11  
1, 2, 3, 4**, 7,  
8A, 8B, 9, 10, 11  
1, 2, 3, 4**, 7,  
8A, 8B, 9, 10, 11  
Group C end-point electrical  
2, 3, 7,  
8A, 8B  
2, 3, 7,  
8A, 8B  
1, 2, 3, 7, 8A,  
8B, 9, 10, 11 ∆  
parameters  
(see 4.4)  
9
Group D end-point electrical  
parameters (see 4.4)  
2, 3, 8A, 8B  
1, 7, 9  
2, 3, 8A, 8B  
1, 7, 9  
2, 3, 8A, 8B  
10  
Group E end-point electrical  
parameters (see 4.4)  
1, 7, 9  
1/ Blank spaces indicate tests are not applicable.  
2/ Any or all subgroups may be combined when using high-speed testers.  
3/ Subgroups 7 and 8 functional tests shall verify the functionality for unprogrammed devices or that the altered item  
drawing pattern exists for programmed devices.  
4/ * indicates PDA applies to subgroup 1 and 7.  
5/ ** see 4.4.1c.  
6/ indicates delta limit (see table IIB) shall be required where specified, and the delta values shall be computed with  
reference to the previous interim electrical parameters (see line 1).  
7/ See 4.4.1d  
TABLE IIB. Delta limits at +25°C.  
Parameter 1/  
Device types  
All  
IDD  
IOZ  
±10% of specified value of table IA  
±10% of specified value of table IA  
±10 ns  
tPBLH, tPBHL  
1/ The above parameter shall be recorded before and after  
the required burn-in and life tests to determine the delta.  
SIZE  
STANDARD  
5962-92156  
A
MICROCIRCUIT DRAWING  
DEFENSE SUPPLY CENTER COLUMBUS  
COLUMBUS, OHIO 43218-3990  
REVISION LEVEL  
J
SHEET  
18  
DSCC FORM 2234  
APR 97  