 浏览型号5962-0421901QUA的Datasheet PDF文件第127页浏览型号5962-0421901QUA的Datasheet PDF文件第128页浏览型号5962-0421901QUA的Datasheet PDF文件第129页浏览型号5962-0421901QUA的Datasheet PDF文件第130页浏览型号5962-0421901QUA的Datasheet PDF文件第132页浏览型号5962-0421901QUA的Datasheet PDF文件第133页浏览型号5962-0421901QUA的Datasheet PDF文件第134页浏览型号5962-0421901QUA的Datasheet PDF文件第135页  
MIL-PRF-38535K  
APPENDIX C  
TABLE C-I. Group E (RHA) TCI/QCI test for class Q, class V and class Y. –continued.  
MIL-STD-883 test method and conditions  
Minimum sample size quantity (accept no.)  
Tests  
1/ 2/  
Subgroups  
Class Q  
Class V  
Class Y  
(class level B)  
(class level S)  
(class level S)  
a. Dose rate upset test  
(Transient irradiation test  
a. For Digital TM1021  
For Linear TM1023  
(temperature at 25°C)  
2(0) devices/wafer or  
11(0) devices/wafer lot  
6/  
a. For Digital TM1021  
For Linear TM1023  
(temperature at 25°C)  
2(0) devices/wafer or  
11(0) devices/wafer lot  
6/  
a. For Digital TM 1021  
For Linear TM1023  
(temperature at 25°C)  
2(0) devices/wafer or  
11(0)devices/inspection lot  
5/  
Subgroup 3  
11/  
b. End point electrical  
parameters test  
b. As specified in  
accordance with  
device specification  
b. As specified in  
accordance with  
device specification  
b. As specified in  
accordance with  
device specification  
Subgroup 4  
Radiation dose rate  
induced latch-up test  
TM 1020  
As specified in the  
device specification  
TM 1020  
As specified in the  
device specification  
TM 1020  
As specified in the  
device specification  
12/  
Subgroup 5  
Single event effects (SEE)  
test  
ASTM F-1192 or JESD57  
4(0) devices or  
As specified in the  
device specification  
ASTM F-1192 or JESD57  
4(0) devices or  
As specified in the  
device specification  
13/  
Note: The screening and QCI/TCI tables from MIL-PRF-38535 and MIL-STD-883 Test Methods 5004 and 5005 have been  
combined for consistency. A future revision of MIL-STD-883 will reflect this change as well. Manufacturers shall document in  
their QM plan the screening and QCI/TCI requirements to either MIL-PRF-38535 or MIL-STD-883.  
1/ Group E tests may be performed prior to device screening. Parts used for one subgroup test may not be used for other subgroups  
but may be used for higher levels in the same subgroup. End point electrical parameters as specified in accordance with device  
specification.  
2/ For devices with solder terminations, group E subgroups test may be performed without balls and columns.  
3/ The radiation hardness assurance capability level (RHACL)/radiation assurance in the SPEC level is the ratio of the capability level  
to the specification level of devices fluence. Subgroups shall be invoked when the radiation hardness assurance capability level  
(RHACL) specification requirements of > 10 are not met. For an example, if RHACL/SPEC ratio is > 10 then this test may not be  
required, but if the RHACL/SPEC ratio falls within > 1 and ≤ 10 then the subgroup test is required.  
4/ This test is to be conducted only when specified in the purchase order or contract. Neutron irradiation test (Displacement damage  
test) is not required for MOS devices unless bipolar elements are included by design.  