TABLE I. Electrical performance characteristics. 1/ 2/
Conditions 3/
1.425V VCCA 1.575V
Group A
subgroups
Device
type
Test
Symbol
Limits
Unit
-55C T +125C
J
unless otherwise specified
Min
Max
For All I/O Standards
TJ = 25oC
01 - 04
05 - 08
01 - 04
05 - 08
50
30
Standby supply current
for core power supply
1,2,3
1,2,3
mA
mA
I
CCA
TJ = 125oC
500
150
Standby supply current
for I/O power supply
TJ = 25oC
1,2,3
1,2,3
All
All
10
35
mA
mA
I
CCI
TJ = 125oC
Standby supply current
TJ = 25oC
1,2,3
All
7
mA
I
CCDA
for V
power supply
CCDA
TJ = 125oC
1,2,3
1,2,3
1,2,3
1,2,3
1,2,3
1,2,3
1,2,3
All
All
All
All
All
All
All
10
1
mA
A
A
A
A
A
A
mA
mA
Input leakage current …
low
VIN = GND, TJ = 25oC
VIN = GND, TJ = 125oC
VIN = VCCI, TJ = 25oC
VIN = VCCI, TJ = 125oC
VIN = VCCI, TJ = 25oC
VIN = VCCI, TJ = 125oC
I
IL
5
Input leakage current …
high
1
I
IH
5
Three-state output current
leakage
1
I
OZ
5
Standby supply current
for VCCDIFFA differential
pairs
ICCDIFFA
VIN = VCCI, TJ = 25oC
1,2,3
All
3.13
3.7
VIN = VCCI, TJ = 125oC
See 4.4.1e
1,2,3
All
All
Functional tests
FT 4/
7,8A,8B
C
COUT
&
&
IN
See 4.4.1c
I/O Input Capacitance
4
All
15
pF
f = 100 kHz, V 0 V
IN
C
INCLK
3.3V LVTTL
3.3V I/O supply
1,2,3
1,2,3
1,2,3
1,2,3
1,2,3
All
All
All
All
All
3.0
-0.3
2.0
3.6
0.8
3.6
0.4
V
V
V
V
V
V
CCI
Low level input voltage
High level input voltage
Low level output voltage
High level output voltage
V
IL
V
IH
V
V
I
I
= 24 mA
= 24 mA
OL
OL
2.4
OH
OH
See notes at end of Table I.
SIZE
STANDARD
5962-04221
A
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
REVISION LEVEL
SHEET
C
11
DSCC FORM 2234
APR 97