FEDL87V2107-01
OKI Semiconductor
ML87V2107
•
Setting of Input System Vertical Valid Line Start Position (IVPS)
The input system vertical valid line start position (IVPS) is set in line unit with reference to the input system
vertical reset (IVR: internal signal), generated from IVS, by setting NPVWE[3:0] (SUB:44h-bit[3:0]). The
input data subsequent to IVPS is written in the memory as the valid data.
This value can be set in ±7 lines (15 levels) with regard to the initial value (NPVWE[3:0] = 8h).
However, when the valid number of data lines is set to 304/254 by setting VBID = 1 in ITU-R BT.656
input/output mode, the phase in the vertical direction cannot be adjusted.
Table F1-1-3 (2) Input System Vertical Valid Line Start Position
VMD
IVPS position (number of IHS’s from IVR)
R656I
VBID
NPVWE=1h
NPVWE=8h
(default)
20
NPVWE=Fh
[1]
[0]
……
……
(-7 lines)
(+7 lines)
27
0
0
1
X
X
0
0
0
0
0
1
0
13
7
……
……
……
……
……
……
……
……
14
21
14*1
21 *1
28 *1
1
1
1
0
0
0
0
1
0
1
9*1
5
16 *1
23 *1
1
5
5
5
5
1
5
Others
Test modes (not settable)
*: In the case of field B, it is +1.
7lines
7lines
IVS
IHS
IVPS
#IVR
288(304)/243(254)lines
#IWE/IRE
YI[7:0]
CI[8:0]
: Valid data
#: Internal signal
Figure F1-1-3 (3) Input System Vertical Valid Line Start Timing
19/152