FEDL87V2107-01
OKI Semiconductor
ML87V2107
1.1.4 Input System Sync. Signal Polarity Inversion Setting
Negative polarity IVS can also be supported by setting the I2C-bus setting register IVSINV (SUB:42h-bit[0]).
Moreover, with regard to field detection, setting is possible even when setting the internal IVR generation edge.
Table F1-1-4 (1) IVINV Setting
IVSINV
Recommended input IVS polarity
Positive (default)
Negative
IVR generation edge
Rising edge
Falling edge
0
1
IVSINV = 0
IVS
IVSINV = 1
IVS
#IWE
#IWE
Value set by
NPVWE[3:0]
Value set by
NPVWE[3:0]
Figure F1-1-4 (1) Support of Input System Vertical Sync. Signal Polarity Inversion
Negative polarity IHS can also be supported by setting the I2C-bus setting register IHSINV (SUB:42h-bit[1]).
Table F1-1-4 (2) IHSINV Setting
IHSINV
Input IHS polarity
Positive (default)
Negative
IHSINV = 0
IHS
IHSINV = 1
IHS
#IWE
#IWE
Value set by
NPHWE[7:0]
Value set by
NPHWE[7:0]
Figure F1-1-4 (2) Support of Input System Horizontal Sync. Signal Polarity Inversion
21/152