Table II shows the data in the Special Function Register that  
will be transferred to the output bus by driving HBE HIGH  
(with SFR HIGH) and initiating a read cycle (driving RD and  
CS LOW with WR HIGH as shown in Figure 4.) The Power  
Fail flag in the SFR is set when the power supply falls below  
about 3V. The flag also means that a new calibration has been  
started, and any data written to the SFR has been lost. Thus,  
the ADC7802 will again be in the Transparent Mode. Writing  
a LOW to D5 in the SFR resets the Power Fail flag. The Cal  
Error flag in the SFR is set when an overflow occurs during  
calibration, which may happen in very noisy systems. It is  
reset by starting a calibration, and remains low after a  
calibration without an overflow is completed.  
Writing a HIGH to D3 in the FSR puts the ADC7802 in the  
Power Down Mode. Power consumption is reduced to 50µW  
and D3 remains HIGH. To exit Power Down Mode, either  
write a LOW to D3 in the SFR, or initiate a calibration by  
sending a LOW to the CAL pin or writing a HIGH to D1.  
During Power Down Mode, a pulse on CS and WR will  
initiate a single conversion, then the ADC7802 will revert to  
power down.  
PIN  
FUNCTION  
DESCRIPTION  
Table III shows how instructions can be transferred to the  
Special Function Register by driving HBE HIGH (with SFR  
HIGH) and initiating a write cycle (driving WR and CS  
LOW with RD HIGH.) The timing is shown in Figure 3. Note  
that writing to the SFR also initiates a new conversion.  
D0  
Mode Status  
If LOW, Transparent Mode enabled for  
data latches. If HIGH, Latched Output  
Mode enabled.  
D1  
CAL Flag  
If HIGH, calibration cycle in progress.  
D2  
D3  
D4  
Reserved for factory use.  
If HIGH, in Power Down Mode.  
Reserved for factory use.  
Power Down Status  
POWER FAIL Flag  
CAL ERROR Flag  
BUSY Flag  
CONTROL LINES  
D5  
D6  
D7  
If HIGH, a power supply failure has  
occurred. (Supply fell below 3V.)  
Table IV shows the functions of the various control lines on  
the ADC7802. The use of standard CS, RD and WR control  
signals simplifies use with most microprocessors. At the  
same time, flexibility is assured by availability of status  
information and control functions, both through the SFR and  
directly on pins.  
If HIGH, an overflow occured during  
calibration.  
If HIGH, conversion or calibration in  
progress.  
NOTE: These data are transferred to the bus when a read cycle is initiated  
with SFR and HBE HIGH. Reading the SFR with SFR HIGH and HBE LOW  
is reserved for factory use at this time, and will yield unpredictable data.  
TABLE II. Reading the Special Function Register.  
CS/WR  
SFR/HBE  
D0  
D1  
D3  
D5  
D7  
D2/D4/D6  
Enables Transparent Mode for Data Latches.  
Enables Latched Output Mode for Data Latches.  
Initiates Calibration Cycle.  
Resets Power Fail flag.  
Activates Power Down Mode  
LOW  
LOW  
LOW  
LOW  
LOW  
HIGH  
HIGH  
HIGH  
HIGH  
HIGH  
LOW  
HIGH  
X
X
X
X
X
HIGH  
X
LOW  
LOW  
LOW  
LOW  
HIGH  
X
X
X
LOW  
X
LOW  
LOW  
LOW  
LOW  
LOW  
LOW  
LOW  
LOW  
LOW  
LOW  
X
NOTES: (1) In Power Down Mode, a pulse on CS and WR will initiate a single conversion, then the ADC7802 will revert to power down. (2) X means it can be  
either HIGH or LOW without affecting this action. Writing HIGH to D2, D3, D4 or D6, or writing with SFR HIGH and HBE LOW, may result in unpredictable behavior.  
These modes are reserved for factory use at this time.  
TABLE III. Writing to the Special Function Register.  
CS  
RD  
WR  
SFR  
HBE  
CAL  
BUSY  
OPERATION  
X
X
1
0
0
0
0
0
0
0
X
X
X
1
0
0
1
0
1
0
X
X
X
01  
1
1
0
1
0
1
X
X
X
0
0
0
1
1
1
1
X
X
X
X
0
1
1
1
0
0
01  
X
1
1
1
1
1
1
1
X
0
X
1
X
X
1
X
X
X
Initiates calibration cycle.  
Conversion or calibration in process. Inhibits new conversion from starting.  
None. Outputs in Hi-Z State.  
Initiates conversion.  
Low byte conversion results output on data bus.  
High byte conversion results output on data bus.  
Write to SFR and rising edge on WR initiates conversion.  
Contents of SFR output on data bus.  
Reserved for factory use.  
Reserved for factory use. (Unpredictable data on data bus.)  
1
TABLE IV. Control Line Functions.  
®
ADC7802  