CHARACTERISTICS & SPECIFICATIONS
4.2 Recommended Operating Conditions
Voltage Specification
Symbol Min
-40
Parameter
Typ Max Unit
Operating temperature
+85 ◦C
Analog and digital ground 1 AGND DGND
0.0
AVDD+0.3 4.0 5.25
V
V
V
V
V
V
Regulator input voltage2
Analog positive supply3
Digital positive supply 3
Digital RTC supply
VHIGH
AVDD
CVDD
RTCVDD
IOVDD
2.75
1.65
1.2
2.8
1.8 1.95
1.5 1.95
3.6
I/O positive supply3
1.8
2.8
3.6
1
2
3
Must be connected together as close the device as possible for latch-up immunity.
At least 4.0 V is required for compliant USB level.
Regulator output of the device.
Oscillator Specification
Parameter
Symbol
XTALI
Min
Typ
Max Unit
Input clock frequency1
11 12.2882
13
60
MHz
%
Input clock duty cycle
Oscillator frequency tolerance
Startup time
Internal clock frequency, USB connected
Internal clock frequency, USB disconnected
RTC clock frequency3
40
60
50
+/-10
1
ppm
ms
CLKU
CLKI
XTALI_RTC
60
98
MHz
MHz
32768
+/-100
1000
Hz
ppm
ms
RTC frequency tolerance
RTC oscillator startup time
1
The maximum sample rate that can be played with correct speed is XTALI/128. With 11 MHz
XTALI sample rates over 85937 Hz are played at 85937 Hz.
2
When full speed (FS) or high speed (HS) USB is used it is recommended that XTAL of
3
12.0MHz 0r 12.288MHz is used. The 32kHz crystal is optional, but required for RTC time
counter.
Version: 0.2, 2012-03-16