 浏览型号HD6433846XXXH的Datasheet PDF文件第113页浏览型号HD6433846XXXH的Datasheet PDF文件第114页浏览型号HD6433846XXXH的Datasheet PDF文件第115页浏览型号HD6433846XXXH的Datasheet PDF文件第116页浏览型号HD6433846XXXH的Datasheet PDF文件第118页浏览型号HD6433846XXXH的Datasheet PDF文件第119页浏览型号HD6433846XXXH的Datasheet PDF文件第120页浏览型号HD6433846XXXH的Datasheet PDF文件第121页  
Bit 3: Direct transfer on flag (DTON)  
This bit designates whether or not to make direct transitions among active (high-speed), active  
(medium-speed) and subactive mode when a SLEEP instruction is executed. The mode to which  
the transition is made after the SLEEP instruction is executed depends on a combination of this  
and other control bits.  
Bit 3  
DTON  
Description  
0
(initial value)  
When a SLEEP instruction is executed in active mode, a transition  
is made to standby mode, watch mode, or sleep mode  
When a SLEEP instruction is executed in subactive mode, a transition is made to  
watch mode or subsleep mode  
1
When a SLEEP instruction is executed in active (high-speed) mode, a direct  
transition is made to active (medium-speed) mode if SSBY = 0, MSON = 1, and  
LSON = 0, or to subactive mode if SSBY = 1, TMA3 = 1, and LSON = 1  
When a SLEEP instruction is executed in active (medium-speed) mode, a direct  
transition is made to active (high-speed) mode if SSBY = 0, MSON = 0, and  
LSON = 0, or to subactive mode if SSBY = 1, TMA3 = 1, and LSON = 1  
When a SLEEP instruction is executed in subactive mode, a direct transition is  
made to active (high-speed) mode if SSBY = 1, TMA3 = 1, LSON = 0, and MSON  
= 0, or to active (medium-speed) mode if SSBY = 1, TMA3 = 1, LSON = 0, and  
MSON = 1  
Bit 2: Medium speed on flag (MSON)  
After standby, watch, or sleep mode is cleared, this bit selects active (high-speed) or active  
(medium-speed) mode.  
Bit 2  
MSON  
Description  
0
1
Operation in active (high-speed) mode  
Operation in active (medium-speed) mode  
(initial value)  