CLASS
OCTAL STYLE 10 AMP GENERAL PURPOSE RELAY
A314 & 250
Struthers-Dunn
RELAYS CAN BE ORDERED EITHER BY MAGNECRAFT OR STRUTHERS-DUNN PART NUMBERS LISTED BELOW
COIL
CROSS REFERENCE TO
Measured @ 25˚C
DUAL MARKED PART NUMBERS
CONTACT
CONFIGU-
RATION
NOMINAL
RESIS-
NOMINAL
POWER
NOMINAL
POTTER &
BRUMFIELD
Struthers-Dunn
IDEC
INPUT
TANCE
SERIES A314
CLASS 250CP
VOLTAGE
*
AC OPERATED
24 VAC
120VAC
24 VAC
A314XAX48P-24A
A314XAX48P-120A
A314XBX48P-24A
A314XBX48P-120A
A314XBX48P-240A
-
-
W250ACPX-3
W250ACPX-4
W250ACPX-8
W250ACPX-9
W250ACPX-10
-
-
-
-
2.0VA
2.0VA
2.75VA
2.75VA
SPDT
SPDT
DPDT
DPDT
DPDT
KRPA5AG (or GF) -24
KRPA5AG (or GF) -120
KRPA11AG (or GF) -24
KRPA11AG (or GF) -120
KRPA11AG (or GF) -240
RR2P-U-AC24V
RR2P-U-AC120V
RR2P-U-AC240V
120VAC
240 VAC, 60 Hz
220 VAC, 50 Hz
24 VAC
120 VAC
240 VAC. 60 Hz
220 VAC, 50 Hz
-
-
-
2.75VA
2.75VA
2.75VA
A314XCX48P-24A
A314XCX48P-120A
A314XCX48P-240A
RR3PA-U-AC24V
RR3PA-U-AC120V
RR3PA-U-AC240V
W250ACPX-13
W250ACPX-14
W250ACPX-15
3PDT
3PDT
3PDT
KRPA14AG (or GF) -24
KRPA14AG (or GF) -120
KRPA14AG (or GF) -240
-
2.75VA
AC OPERATED WITH INDICATOR LAMP
24 VAC
120 VAC
240 VAC. 60 Hz
220 VAC, 50 Hz
24 VAC
120 VAC
240 VAC. 60 Hz
220 VAC, 50 Hz
A314XBX48PL-24A
A314XBX48PL-120A
A314XBX48PL-240A
RR2P-UL-AC24V
RR2P-UL-AC120V
RR2P-UL-AC240V
W250ANCPX-26
W250ANCPX-27
W250ANCPX-28
2.0VA
2.0VA
2.75VA
DPDT
DPDT
DPDT
KRPA11AN (or NF) -24
KRPA11AN (or NF) -120
KRPA11AN (or NF) -240
A314XCX48PL-24A
A314XCX48PL-120A
A314XCX48PL-24OA
RR3PA-UL-AC24V
RR3PA-UL-AC120V
RR3PA-UL-AC240V
W250ANCPX-29
W250ANCPX-30
W250ANCPX-31
2.0VA
2.0VA
2.75VA
3PDT
3PDT
3PDT
KRPA14AN (or NF) -24
KRPA14AN (or NF) -120
KRPA14AN (or NF) -240
DC OPERATED
12 VDC
24 VDC
12VDC
24 VDC
12 VDC
24 VDC
A314XAX48P-12D
A314XAX48P-24D
A314XBX48P-12D
A314XBX48P-24D
A314XCX48P-12D
A314XCX48P-24D
-
-
W250CPX-2
W250CPX-3
W250CPX-6
W250CPX-7
W250CPX-10
W250CPX-11
120 Ω
472 Ω
120 Ω
472 Ω
120 Ω
472 Ω
1.2W
1.2W
1.2W
1.2W
1.2W
1.2W
SPDT
SPDT
DPDT
DPDT
3PDT
3PDT
KRPA5DG (or GF) -12
KRPA5DG (or GF) -24
KRPA11DG (or GF) -12
KRPA11DG (or GF) -24
KRPA14DG (or GF) -12
KRPA14DG (or GF) -24
RR2P-U-DC12V
RR2P-U-DC24V
RR3PA-U-DC12V
RR3PA-U-DC24V
DC OPERATED WITH INDICATOR LAMP
24 VDC
24 VDC
A314XBX48PL-24D
A314XCX48PL-24D
RR2P-UL-DC24V
RR3PA-UL-DC24V
W250NCPX-20
W250NCPX-21
472 Ω
472 Ω
1.2 W
1.2 W
DPDT
3PDT
KRPA11DN (or NF) -24
KRPA14DN (or NF) -24
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION
*
F = GOLD FLASHED
CONTACT RATINGS WITH BLOW-OUT MAGNET
150 VDC
POLES
DPDT
120 VAC
240 VAC
30 VDC
10 AMP
1/2 HP
12 AMP
1/3 HP
10 AMP
3 AMP
-
-
RELAYS FOR DC SWITCHING
Measured @ 25˚C
COIL
CONTACT NO. OF PINS
NOMINAL
PART
NUMBERS
NOMINAL
RESISTANCE
(OHMS)
NOMINAL
POWER
CONFIGU-
RATION
OCTAL
STYLE
INPUT
VOLTAGE
AC OPERATED WITH BLOW-OUT MAGNET
A314XBX48P69-24A
A314XBX48P69-120A
24 VAC
120VAC
-
-
2.0 VA
2.0 VA
DPDT
DPDT
8 PIN
8 PIN
DC OPERATED WITH BLOW-OUT MAGNET
A314XBX48P69-12D
A314XBX48P69-24D
A314XBX48P69-110D
12 VDC
24 VDC
110 VDC
120 Ω
472 Ω
10,000 Ω
1.2 W
1.2 W
1.2 W
DPDT
DPDT
DPDT
8 PIN
8 PIN
8 PIN
RELAYS USING MAGNETIC BLOW-OUT MAGNETS ARE NOT AGENCY APPROVED.
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 18