UL62H256A
Characteristics
All voltages are referenced to VSS = 0 V (ground).
All characteristics are valid in the power supply voltage range and in the operating temperature range specified.
Dynamic measurements are based on a rise and fall time of ≤ 5 ns, measured between 10 % and 90 % of VI, as well as
input levels of VIL = 0.2 V and VIH = 2.8 V. The timing reference level of all input and output signals is 1.5 V,
with the exception of the tdis-times and ten-times, in which cases transition is measured ±200 mV from steady-state voltage.
a
Absolute Maximum Ratings
Symbol
Min.
Max.
Unit
Power Supply Voltage
Input Voltage
VCC
VI
-0.3
-0.5
-0.5
-
4.6
VCC + 0.5
VCC + 0.5
1
V
V
b
b
Output Voltage
VO
PD
Ta
V
Power Dissipation
Operating Temperature
W
°C
K-Type
A-Type
-40
-40
85
125
Storage Temperature
Tstg
-65
150
°C
Output Short-Circuit Current
at VCC = 3.3 V and VO = 0 V c
| IOS
|
100
mA
a
Stresses greater than those listed under „Absolute Maximum Ratings“ may cause permanent damage to the device. This is a stress rating
only, and functional operation of the device at condition above those indicated in the operational sections of this specification is not implied.
Exposure to absolute maximum rating conditions for extended periods may affect reliability
b
c
Maximum voltage is 4.6 V
Not more than 1 output should be shorted at the same time. Duration of the short circuit should not exceed 30 s.
Recommended
Symbol
VCC
Conditions
Min.
2.5
Max.
3.6
Unit
V
Operating Conditions
Power Supply Voltage
Input Low Voltage d
VIL
-0.3
2.0
0.5
V
Input High Voltage
VIH
VCC + 0.3
V
d
-2 V at Pulse Width 30 ns
May 07, 2004
3