Product specification
6
9
Chip Resistor Surface Mount
RC
SERIES
0402
TESTS AND REQUIREMENTS
Table 4
Test condition, procedure and requirements
TEST
Temperature
Coefficient of
Resistance
(T.C.R.)
TEST METHOD
IEC 60115-1 4.8
PROCEDURE
At +25/–55 °C and +25/+125 °C
REQUIREMENTS
Refer to table 2
Formula:
R
2
–R
1
T.C.R= ------------------------- ×10
6
(ppm/°C)
R
1
(t
2
–t
1
)
Where
t
1
=+25 °C or specified room temperature
t
2
=–55 °C or +125 °C test temperature
R
1
=resistance at reference temperature in ohms
R
2
=resistance at test temperature in ohms
Life/Endurance
IEC 60115-1 4.25.1
At 70±5 °C for 1,000 hours, RCWV applied for
1.5 hours on, 0.5 hour off, still air required
±(1.0%+0.05
Ω)
for 1% tol.
±(3.0%+0.05
Ω)
for 5% tol.
<100 mΩ for Jumper
High
Temperature
Exposure/
Endurance at
Upper Category
Temperature
Moisture
Resistance
IEC 60068-2-2
1,000 hours at 155±5 °C, unpowered
±(1.0%+0.05
Ω)
for 1% tol.
±(2.0%+0.05
Ω)
for 5% tol.
<50 mΩ for Jumper
MIL-STD-202G Method-106G
Each temperature / humidity cycle is defined at 8
hours, 3 cycles / 24 hours for 10d. with 25 °C /
65 °C 95% R.H, without steps 7a & 7b,
unpowered
Parts mounted on test-boards, without
condensation on parts
Measurement at 24±2 hours after test conclusion
±(0.5%+0.05
Ω)
for 1% tol.
±(2.0%+0.05
Ω)
for 5% tol.
<100 mΩ for Jumper
Thermal Shock
MIL-STD-202G Method-107G
-55/+125 °C
Number of cycles required is 300. Devices
unmounted
Maximum transfer time is 20 seconds. Dwell time
is 15 minutes. Air – Air
±(0.5%+0.05
Ω)
for 1% tol.
±(1%+0.05
Ω)
for 5% tol.
<50 mΩ for Jumper
Short Time
Overload
IEC60115-1 4.13
2.5 times of rated voltage or maximum overload
voltage whichever is less for 5 sec at room
temperature
±(1.0%+0.05
Ω)
for 1% tol.
±(2.0%+0.05
Ω)
for 5% tol.
<50 mΩ for Jumper
No visible damage
www.yageo.com
Jan 05, 2011 V.6