Spartan and Spartan-XL Families Field Programmable Gate Arrays  
Spartan-XL Pin-to-Pin Input Parameter Guidelines  
Testing of switching parameters is modeled after testing  
methods specified by MIL-M-38510/605. All devices are  
100% functionally tested. Pin-to-pin timing parameters are  
derived from measuring external and internal test patterns  
and are guaranteed over worst-case operating conditions  
(supply voltage and junction temperature). Listed below are  
representative values for typical pin locations and normal  
clock loading.  
Spartan-XL Setup and Hold  
Speed Grade  
-5  
-4  
Symbol  
Description  
Device  
Max  
Max  
Units  
Input Setup/Hold Times Using Global Clock and IFF  
T
/T  
No Delay  
Full Delay  
XCS05XL  
XCS10XL  
XCS20XL  
XCS30XL  
XCS40XL  
XCS05XL  
XCS10XL  
XCS20XL  
XCS30XL  
XCS40XL  
1.1/2.0  
1.0/2.2  
0.9/2.4  
0.8/2.6  
0.7/2.8  
3.9/0.0  
4.1/0.0  
4.3/0.0  
4.5/0.0  
4.7/0.0  
1.6/2.6  
1.5/2.8  
1.4/3.0  
1.3/3.2  
1.2/3.4  
5.1/0.0  
5.3/0.0  
5.5/0.0  
5.7/0.0  
5.9/0.0  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
SUF HF  
T
/T  
H
SU  
Notes:  
1. IFF = Input Flip-Flop or Latch  
2. Setup time is measured with the fastest route and the lightest load. Hold time is measured using the furthest distance and a  
reference load of one clock pin per IOB/CLB.  
Capacitive Load Factor  
Figure 35 shows the relationship between I/O output delay  
and load capacitance. It allows a user to adjust the specified  
3
output delay if the load capacitance is different than 50 pF.  
For example, if the actual load capacitance is 120 pF, add  
2
2.5 ns to the specified delay. If the load capacitance is 20  
pF, subtract 0.8 ns from the specified output delay.  
Figure 35 is usable over the specified operating conditions  
1
of voltage and temperature and is independent of the output  
slew rate control.  
0
-1  
-2  
0
20  
40  
60  
80  
100  
120  
140  
Capacitance (pF)  
DS060_35_080400  
Figure 35: Delay Factor at Various Capacitive Loads  