 浏览型号XC3S1600E-4FGG320C的Datasheet PDF文件第101页浏览型号XC3S1600E-4FGG320C的Datasheet PDF文件第102页浏览型号XC3S1600E-4FGG320C的Datasheet PDF文件第103页浏览型号XC3S1600E-4FGG320C的Datasheet PDF文件第104页浏览型号XC3S1600E-4FGG320C的Datasheet PDF文件第106页浏览型号XC3S1600E-4FGG320C的Datasheet PDF文件第107页浏览型号XC3S1600E-4FGG320C的Datasheet PDF文件第108页浏览型号XC3S1600E-4FGG320C的Datasheet PDF文件第109页  
R
DC and Switching Characteristics  
Table 2: Supply Voltage Thresholds for Power-On Reset  
Symbol  
VCCINTT  
VCCAUXT  
VCCO2T  
Description  
Threshold for the VCCINT supply  
Threshold for the VCCAUX supply  
Threshold for the VCCO Bank 2 supply  
Min  
0.4  
0.8  
0.4  
Max  
1.0  
Units  
V
V
V
2.0  
1.0  
Notes:  
1.  
V
, V  
, and V  
supplies may be applied in any order.  
CCO  
CCINT CCAUX  
2. To ensure successful power-on, V  
no dips at any point.  
, V  
Bank 2, and V  
supplies must rise through their respective threshold-voltage ranges with  
CCINT CCO  
CCAUX  
Table 3: Power Voltage Levels Necessary for Preserving RAM Contents  
Symbol  
VDRINT  
VDRAUX  
VDRO  
Description  
VCCINT level required to retain RAM data  
Min  
1.0  
2.0  
1.0  
Units  
V
V
V
VCCAUX level required to retain RAM data  
VCCO level required to retain RAM data  
Notes:  
1. RAM contents include configuration data.  
Table 4: General Recommended Operating Conditions  
Symbol  
Description  
Junction temperature  
Min  
0
Nom  
Max  
85  
Units  
°C  
°C  
V
TJ  
Commercial  
Industrial  
-
–40  
-
100  
VCCINT  
Internal supply voltage  
Output driver supply voltage  
Auxiliary supply voltage  
1.140  
1.140  
2.375  
1.200  
-
1.260  
3.450  
2.625  
(1)  
VCCO  
V
(2)  
VCCAUX  
2.500  
V
Notes:  
1. The V  
range given here spans the lowest and highest operating voltages of all supported I/O standards. The recommended V  
range  
CCO  
CCO  
specific to each of the single-ended I/O standards is given in Table 7, and that specific to the differential standards is given in Table 9.  
2. Only during DCM operation, it is recommended that the rate of change of V not exceed 10 mV/ms.  
CCAUX  
2
www.xilinx.com  
DS312-3 (v1.0) March 1, 2005  
Advance Product Specification  