R
Functional Description  
The CLKFX_DIVIDE is an integer ranging from 1 to 32,  
inclusive and forms the denominator in Equation 1. For  
example, if CLKFX_MULTIPLY = 5 and CLKFX_DIVIDE = 3,  
the frequency of the output clock signal is 5/3 that of the  
input clock signal. These attributes and their acceptable  
ranges are described in Table 34.  
and output clock edges coincide every three CLKIN input  
periods, which is equivalent in time to five CLKFX output  
periods.  
Smaller CLKFX_MULTIPLY and CLKFX_DIVIDE values  
result in faster lock times. Therefore, CLKFX_MULTIPLY  
and CLKFX_DIVIDE must be factored to reduce their values  
wherever possible. For example, given CLKFX_MULTIPLY  
= 9 and CLKFX_DIVIDE = 6, removing a factor of three  
yields CLKFX_MULTIPLY = 3 and CLKFX_DIVIDE = 2.  
While both value-pairs result in the multiplication of clock  
frequency by 3/2, the latter value-pair enables the DLL to  
lock more quickly.  
Table 34: DFS Attributes  
Attribute  
Description  
Values  
CLKFX_MULTIPLY  
Frequency  
multiplier  
constant  
Integer from  
2 to 32,  
inclusive  
CLKFX_DIVIDE  
Frequency divisor Integer from  
Phase Shifter (PS)  
constant  
1 to 32,  
The DCM provides two approaches to controlling the phase  
of a DCM clock output signal relative to the CLKIN signal:  
First, eight of the nine DCM clock outputs CLK0, CLK90,  
CLK180, CLK270, CLK2X, CLK2X180, CLKFX, and  
CLKFX180 provide either quadrant or half-period phase  
shifting of the input clock.  
inclusive  
Any combination of integer values can be assigned to the  
CLKFX_MULTIPLY and CLKFX_DIVIDE attributes, pro-  
vided that two conditions are met:  
1. The two values fall within their corresponding ranges,  
as specified in Table 34.  
Second, the PS unit provides additional fine phase shift  
control of all nine DCM outputs. The PS unit accomplishes  
2. The f  
output frequency calculated in Equation 1  
falls within the DCM’s operating frequency  
specifications (see Table 107 in Module 3).  
this by introducing a “fine phase shift” delay (T ) between  
CLKFX  
PS  
the CLKFB and CLKIN signals inside the DLL unit. In FIXED  
phase shift mode, the fine phase shift is specified at design  
1
th  
time with a resolution down to /  
of a CLKIN cycle or  
256  
DFS With or Without the DLL  
one delay step (DCM_DELAY_STEP), whichever is greater.  
This fine phase shift value is relative to the coarser quadrant  
or half-period phase shift of the DCM clock output. When  
used, the PS unit shifts the phase of all nine DCM clock out-  
put signals.  
Although the CLKIN input is shared with both units, the DFS  
unit functions with or separately from the DLL unit. Separate  
from the DLL, the DFS generates an output frequency from  
the CLKIN frequency according to the respective  
CLKFX_MULTIPLY and CLKFX_DIVIDE values. Frequency  
synthesis does not require a feedback loop. Furthermore,  
without the DLL, the DFS unit supports a broader operating  
frequency range.  
Enabling Phase Shifting and Selecting an Operat-  
ing Mode  
The CLKOUT_PHASE_SHIFT attribute controls the PS unit  
for the specific DCM instantiation. As described in Table 35,  
this attribute has three possible values: NONE, FIXED, and  
VARIABLE. When CLKOUT_PHASE_SHIFT = NONE, the  
PS unit is disabled and the DCM output clocks are  
phase-aligned to the CLKIN input via the CLKFB feedback  
path. Figure 44a shows this case.  
With the DLL, the DFS unit operates as described above,  
only with the additional benefit of eliminating the clock distri-  
bution delay. In this case, a feedback loop from the CLK0 or  
CLK2X output to the CLKFB input must be present.  
When operating with the DLL unit, the DFS’s CLKFX and  
CLKFX180 outputs are phase-aligned with the CLKIN input  
every CLKFX_DIVIDE cycles of CLKIN and every  
CLKFX_MULTIPLY cycles of CLKFX. For example, when  
CLKFX_MULTIPLY = 5 and CLKFX_DIVIDE = 3, the input  
The PS unit is enabled when the CLKOUT_PHASE_SHIFT  
attribute is set to FIXED or VARIABLE modes. These two  
modes are described in the sections that follow.  
Table 35: PS Attributes  
Attribute  
Description  
Disables the PS component or chooses between  
Values  
CLKOUT_PHASE_SHIFT  
NONE, FIXED, VARIABLE  
Fixed Phase and Variable Phase modes.  
PHASE_SHIFT  
Determines size and direction of initial fine phase  
shift.  
Integers from –255 to +255  