R
QPRO Series Configuration PROMs (XQ) including Radiation-Hardened Series (XQR)
Absolute Maximum Ratings
Symbol
Description
Supply voltage relative to GND
Conditions
–0.5 to +4.0
–0.5 to +12.5
Units
V
V
V
CC
PP
Supply voltage relative to GND
V
V
Input voltage relative to GND
–0.5 to V +0.5
V
IN
CC
V
Voltage applied to High-Z output
Storage temperature (ambient)
–0.5 to V +0.5
V
TS
CC
T
T
–65 to +150
°C
°C
STG
SOL
Maximum soldering temperature (10s @ 1/16 in.)
+260
Notes:
1. Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress
ratings only, and functional operation of the device at these or any other conditions beyond those listed under Operating Conditions
is not implied. Exposure to Absolute Maximum Ratings conditions for extended periods of time may affect device reliability.
Operating Conditions
Symbol
Description
Supply voltage relative to GND
Min
Max
Units
(1)
V
Military
3.0
3.6
V
CC
ceramic package (T = –55°C to +125°C)
C
plastic package (T = –55°C to +125°C)
J
Notes:
1. During normal read operation VPP MUST be connected to V
CC.
DC Characteristics Over Operating Condition
Symbol
Description
Min
Max
Units
V
V
High-level input voltage
Low-level input voltage
High-level output voltage (I
2
V
CC
IH
V
0
0.8
-
V
IL
V
= –3 mA)
OH
2.4
V
OH
V
Low-level output voltage (I = +3 mA)
-
0.4
10
100
300
3
V
OL
OL
I
Supply current, active mode (at maximum frequency)
Supply current, standby mode (XQ1701L)
-
mA
µA
µA
mA
µA
pF
pF
CCA
CCS
I
-
(1)
CCS
I
Supply current, standby mode
(XQR1701L )
Pre-rad (TID)
Post-rad (TID)
-
-
I
Input or output leakage current
–10
10
10
10
L
C
Input capacitance (V = GND, f = 1.0 MHz)
-
-
IN
IN
C
Output capacitance (V = GND, f = 1.0 MHz)
IN
OUT
Notes:
1.
I
, Standby Current is measured at +125°C for pre-radiation specifications and at room temperature for post-radiation
CCS
specifications.
DS062 (v3.0) February 8, 2000
www.xilinx.com
7
Preliminary Product Specification
1-800-255-7778