Preliminary Information
X1288
Figure 8. Valid Data Changes on the SDA Bus
SCL
SDA
Data Stable
Data Change
Data Stable
Figure 9. Valid Start and Stop Conditions
SCL
SDA
Start
Stop
Figure 13. Acknowledge Response From Receiver
SCL from
Master
1
8
9
Data Output
from Transmitter
Data Output
from Receiver
Start
Acknowledge
Figure 11. Slave Address, Word Address, and Data Bytes (128 Byte pages)
Device Identifier
Slave Address Byte
Byte 0
Array
CCR
1
1
0
1
1
0
0
1
1
1
1
R/W
A8
Word Address 1
Byte 1
0
A14
A13
A12
A11
A10
A9
Word Address 0
Byte 2
A7
D7
A6
D6
A5
D5
A4
D4
A3
D3
A2
D2
A1
D1
A0
D0
Data Byte
Byte 3
20 of 31
REV 1.1.30 3/24/04
www.xicor.com