 浏览型号WM9715LGEFL/RV的Datasheet PDF文件第41页浏览型号WM9715LGEFL/RV的Datasheet PDF文件第42页浏览型号WM9715LGEFL/RV的Datasheet PDF文件第43页浏览型号WM9715LGEFL/RV的Datasheet PDF文件第44页浏览型号WM9715LGEFL/RV的Datasheet PDF文件第46页浏览型号WM9715LGEFL/RV的Datasheet PDF文件第47页浏览型号WM9715LGEFL/RV的Datasheet PDF文件第48页浏览型号WM9715LGEFL/RV的Datasheet PDF文件第49页  
Production Data  
WM9715L  
If the SLEN bit is set to ‘1’, then the touchpanel data appears on the AC-Link slot selected by the  
SLT control bits, as shown below. The Slot 0 ‘tag’ bit corresponding to the selected time slot is  
asserted whenever there is new data on that slot.  
REGISTER  
ADDRESS  
BIT  
LABEL  
SLEN  
DEFAULT  
DESCRIPTION  
76h  
3
0
Slot Readback Enable  
0: Disabled (readback through register only)  
1: Enable (readback slot selected by SLT)  
2:0  
SLT  
110  
AC’97 Slot Selection for Touchpanel Data  
000: Slot 5  
001: Slot 6  
101: Slot 10  
110: Slot 11  
111: RESERVED  
Table 28 Returning Touchpanel Data Through an AC-Link Time Slot  
TOUCHPANEL SETTLING TIME  
For accurate touchpanel measurements, some settling time may be required between the switch  
matrix applying a voltage across the touchpanel plate and the ADC sampling the signal. This time  
delay function is built into the WM9715L and can be programmed as shown below.  
REGISTER  
ADDRESS  
BIT  
7:4  
LABEL  
DEL  
DEFAULT  
DESCRIPTION  
76h  
0000  
Touchpanel ADC Settling Time  
(1 frame)  
Table 29 Touchpanel Settling Time Control (1)  
DEL  
DELAY  
DELAY  
(TIME)  
20.8µs  
41.7µs  
83.3µs  
167µs  
333µs  
667µs  
1ms  
(AC-LINK FRAMES)  
0000  
0001  
0010  
0011  
0100  
0101  
0110  
0111  
1000  
1001  
1010  
1011  
1100  
1101  
1110  
1111  
1
2
4
8
16  
32  
48  
64  
96  
128  
160  
192  
224  
256  
288  
1.33ms  
2ms  
2.67ms  
3.33ms  
4ms  
4.67ms  
5.33ms  
6ms  
No delay, switch matrix always on  
Table 30 Touchpanel Settling Time Control (2)  
The total time for co-ordinate or auxiliary measurements to complete is the delay time DEL, plus one  
AC-Link frame (20.8µs). For a pressure measurement, the time taken is DEL plus two AC-Link  
frames (41.6µs).  
PD Rev 4.0 December 2007  
45  