 浏览型号WM9715LGEFL/RV的Datasheet PDF文件第40页浏览型号WM9715LGEFL/RV的Datasheet PDF文件第41页浏览型号WM9715LGEFL/RV的Datasheet PDF文件第42页浏览型号WM9715LGEFL/RV的Datasheet PDF文件第43页浏览型号WM9715LGEFL/RV的Datasheet PDF文件第45页浏览型号WM9715LGEFL/RV的Datasheet PDF文件第46页浏览型号WM9715LGEFL/RV的Datasheet PDF文件第47页浏览型号WM9715LGEFL/RV的Datasheet PDF文件第48页  
WM9715L  
Production Data  
When COO is ‘0’, the WM9715L performs one type of measurement once (in polling mode) or  
continuously (in continuous mode).  
The co-ordinate mode (COO = ‘1’) makes it easier to obtain co-ordinate pairs rather than single co-  
ordinates. In polling-coordinate mode (CTC = ‘0’, COO = ‘1’), the WM9715L performs an X  
measurement, followed by a Y measurement, followed by an additional measurement determined by  
ADCSEL, then stops. In continuous-coordinate mode (CTC = ‘1’, COO = ‘1’), the WM9715L  
continuously repeats a sequence consisting of an X-co-ordinate measurement, followed by a Y co-  
ordinate measurement, followed by an additional measurement determined by ADCSEL (if ADCSEL  
= 000, the sequence is XYXYXY… only).  
DATA READBACK  
The output data word of the touchpanel interface consists of three parts:  
Pen Status (1 bit) – this is also passed to the interrupt logic block, which can be  
programmed to generate an interrupt and/or wake up the WM9715L on pen down (see  
“Interrupt Control”).  
Output data from the touchpanel ADC (12 bits)  
ADCSRC: 3 additional bits that indicate the source of the ADC data. With COO = ‘0’,  
ADCSRC echoes ADCSEL. However, in co-ordinate mode (COO = ‘1’), the WM9715L  
schedules different types of measurements autonomously and sets the ADCSRC bits  
accordingly (see “Measurement Types”).  
This data is stored in register 7Ah, and can be retrieved by reading the register in the usual manner  
(see AC-Link Interface section). Additionally, the data can also be passed to the controller on one of  
the AC-Link time slots not used for audio functions.  
To minimize CPU loading, it is recommended to use interrupt-driven methods rather than polling  
routines for reading touchpanel data. However, where polling routines are used, two methods are  
available for determining when a measurement has finished:  
Reading back the POLL bit. If it has been reset to ‘0’, then the measurement has finished.  
Reading back 7Ah until the new data appears  
REGISTER  
ADDRESS  
BIT  
15  
LABEL  
PNDN  
DEFAULT  
DESCRIPTION  
Pen status (read-only)  
7Ah  
or  
0
0: Pen Up  
AC-Link slot  
selected by  
SLT  
1: Pen Down  
14:12  
ADCSRC  
000  
Touchpanel ADC Source  
000: No measurement  
001: X co-ordinate measurement  
010: Y co-ordinate measurement  
011: Pressure measurement  
(4-wire touchpanels only)  
100: COMP1/AUX1 measurement (pin 29)  
101: COMP2/AUX2 measurement (pin 30)  
110: BMON/AUX3 measurement (pin 31)  
111: WIPER/AUX4 measurement (pin 12)  
Touchpanel ADC Data (read-only)  
Bit 11 = MSB  
11:0  
9
ADCD  
WAIT  
000h  
0
Bit 0 = LSB  
78h  
0: No effect (new ADC data overwrites  
unread data in register 7Ah)  
1: New data is held back, and  
measurements delayed, until register 7Ah is  
read)  
Table 27 Touchpanel Digitiser Data  
To avoid losing data that has not yet been read, the WM9715L can delay overwriting register 7Ah  
with new data until the old data has been read. This function is enabled using the WAIT bit.  
PD Rev 4.0 December 2007  
44  