 浏览型号WM9715LGEFL/RV的Datasheet PDF文件第39页浏览型号WM9715LGEFL/RV的Datasheet PDF文件第40页浏览型号WM9715LGEFL/RV的Datasheet PDF文件第41页浏览型号WM9715LGEFL/RV的Datasheet PDF文件第42页浏览型号WM9715LGEFL/RV的Datasheet PDF文件第44页浏览型号WM9715LGEFL/RV的Datasheet PDF文件第45页浏览型号WM9715LGEFL/RV的Datasheet PDF文件第46页浏览型号WM9715LGEFL/RV的Datasheet PDF文件第47页  
Production Data  
WM9715L  
INITIATION OF MEASUREMENTS  
The WM9715L touchpanel interface supports both polling routines and DMA (direct memory access)  
to control the flow of data from the touchpanel ADC to the host CPU.  
In a polling routine, the CPU starts each measurement individually by writing to the POLL bit (register  
76h, bit 15). This bit automatically resets itself when the measurement is completed.  
REGISTER  
ADDRESS  
BIT  
LABEL  
DEFAULT  
DESCRIPTION  
76h  
10  
15  
CTC  
0
0: Polling mode  
1: Continuous mode (for DMA)  
POLL  
CR  
0
Writing “1” initiates a measurement  
Continuous mode rate (DEL 1111)  
00: 93.75 Hz (every 512 AC-Link frames)  
01: 187.5 Hz (every 256 AC-Link frames)  
10: 375Hz (every 128 AC-Link frames)  
11: 750Hz (every 64 AC-Link frames)  
Continuous mode rate (DEL = 1111)  
00: 8 kHz (every six AC-Link frames)  
01: 12 kHz (every four AC-Link frames)  
10: 24 kHz (every other AC-Link frame)  
11: 48 kHz (every AC-Link frame)  
9:8  
00  
78h  
11  
PDEN  
0
0: measure regardless of pen status  
1: measure only when pen is down (when  
CTC=0 and POLL=1, measurement is  
delayed until pen-down; when CTC=1,  
measurements are stopped on pen-up)  
Table 25 Touchpanel Digitiser Control (Initiation of Measurements)  
In continuous mode (CTC = 1), the WM9715L autonomously initiates measurements at the rate set  
by CR, and supplies the measured data to the CPU on one of the unused AC’97 time slots. DMA-  
enabled CPUs can write the data directly into a FIFO without any intervention by the CPU core. This  
reduces CPU loading and speeds up the execution of user programs in handheld systems.  
Note that the measurement frequency in continuous mode is also affected by the DEL bits (see  
“Touchpanel Settling Time”). The faster rates achieved when DEL = 1111 may be useful when the  
ADC is used for auxiliary measurements.  
MEASUREMENT TYPES  
The ADCSEL control bits determine which type of measurement is performed (see below).  
REGISTER  
ADDRESS  
BIT  
LABEL  
DEFAULT  
DESCRIPTION  
76h  
14:12  
ADCSEL  
000  
Measurement Type (ADC Input Selector)  
000: No measurement  
001: X co-ordinate measurement  
010: Y co-ordinate measurement  
011: Pressure measurement  
100: COMP1/AUX1 measurement (pin 29)  
101: COMP2/AUX2 measurement (pin 30)  
110: BMON/AUX3 measurement (pin 31)  
111: WIPER/AUX4 measurement (pin 12)  
Enable co-ordinate mode  
11  
COO  
0
0: Single measurement according to ADCSEL  
1: X, then Y, then additional measurement  
indicated by ADCSEL  
Table 26 Touchpanel Digitiser Control (Measurement Types)  