 浏览型号WM9715LGEFL/RV的Datasheet PDF文件第18页浏览型号WM9715LGEFL/RV的Datasheet PDF文件第19页浏览型号WM9715LGEFL/RV的Datasheet PDF文件第20页浏览型号WM9715LGEFL/RV的Datasheet PDF文件第21页浏览型号WM9715LGEFL/RV的Datasheet PDF文件第23页浏览型号WM9715LGEFL/RV的Datasheet PDF文件第24页浏览型号WM9715LGEFL/RV的Datasheet PDF文件第25页浏览型号WM9715LGEFL/RV的Datasheet PDF文件第26页  
WM9715L  
Production Data  
AUTOMATIC LEVEL CONTROL  
The WM9715L has an automatic level control that aims to keep a constant recording volume  
irrespective of the input signal level. This is achieved by continuously adjusting the PGA gain so that  
the signal level at the ADC input remains constant. A digital peak detector monitors the ADC output  
and changes the PGA gain if necessary.  
input  
signal  
PGA  
gain  
signal  
after  
ALC  
ALC  
target  
level  
hold decay  
time time  
attack  
time  
Figure 3 ALC Operation  
The ALC function is enabled using the ALCSEL control bits. When enabled, the recording volume  
can be programmed between –6dB and –28.5dB (relative to ADC full scale) using the ALCL register  
bits.  
HLD, DCY and ATK control the hold, decay and attack times, respectively:  
Hold time is the time delay between the peak level detected being below target and the PGA gain  
beginning to ramp up. It can be programmed in power-of-two (2n) steps, e.g. 2.67ms, 5.33ms,  
10.67ms etc. up to 43.7s. Alternatively, the hold time can also be set to zero. The hold time only  
applies to gain ramp-up, there is no delay before ramping the gain down when the signal level is  
above target.  
Decay (Gain Ramp-Up) Time is the time that it takes for the PGA gain to ramp up across 90% of its  
range (e.g. from –15B up to 27.75dB). The time it takes for the recording level to return to its target  
value therefore depends on both the decay time and on the gain adjustment required. If the gain  
adjustment is small, it will be shorter than the decay time. The decay time can be programmed in  
power-of-two (2n) steps, from 24ms, 48ms, 96ms, etc. to 24.58s.  
Attack (Gain Ramp-Down) Time is the time that it takes for the PGA gain to ramp down across 90%  
of its range (e.g. from 27.75dB down to –15B gain). The time it takes for the recording level to return  
to its target value therefore depends on both the attack time and on the gain adjustment required. If  
the gain adjustment is small, it will be shorter than the attack time. The attack time can be  
programmed in power-of-two (2n) steps, from 6ms, 12ms, 24ms, etc. to 6.14s.  
When operating in stereo, the peak detector takes the maximum of left and right channel peak  
values, and any new gain setting is applied to both left and right PGAs, so that the stereo image is  
preserved. However, the ALC function can also be enabled on one channel only. In this case, only  
one PGA is controlled by the ALC mechanism, while the other channel runs independently with its  
PGA gain set through the control register.  
PD Rev 4.0 December 2007  