Production Data  
WM8945  
REGISTER  
ADDRESS  
BIT  
LABEL  
DEFAULT  
DESCRIPTION  
SPKL_SPKVDD  
_ENA  
0
SPKOUTL enable  
10  
0 = Disabled  
1 = Enabled  
Note that SPKOUTL is also  
controlled by SPKL_OP_ENA.  
When powering down SPKOUTL,  
the SPKL_SPKVDD_ENA bit should  
be reset first  
SPKR_OP_ENA  
0
SPKOUTR enable  
0 = Disabled  
7
1 = Enabled  
Note that SPKOUTR is also  
controlled by  
SPKR_SPKVDD_ENA. When  
powering up SPKOUTR, the  
SPKR_OP_ENA bit should be  
enabled first.  
SPKL_OP_ENA  
0
SPKOUTL enable  
0 = Disabled  
6
1 = Enabled  
Note that SPKOUTL is also  
controlled by SPKL_SPKVDD_ENA.  
When powering up SPKOUTL, the  
SPKL_OP_ENA bit should be  
enabled first  
SPKR_MIX_  
ENA  
0
0
0
Right speaker output mixer enable  
0 = Disabled  
3
2
1
1 = Enabled  
SPKL_MIX_ENA  
DACR_ENA  
Left speaker output mixer enable  
0 = Disabled  
1 = Enabled  
Right DAC Enable  
0 = Disabled  
1 = Enabled  
DACR_ENA must be set to 1 when  
processing right channel data from  
the DAC or Digital Beep Generator.  
DACL_ENA  
0
Left DAC Enable  
0 = Disabled  
1 = Enabled  
0
DACR_ENA must be set to 1 when  
processing left channel data from  
the DAC or Digital Beep Generator.  
Table 68 Power Management Control  
THERMAL SHUTDOWN  
The WM8945 incorporates a temperature sensor which detects when the device temperature is within  
normal limits. The temperature status can be read at any time from the TEMP_STS bit, as described  
in Table 69. This bit can be polled at any time, or may output directly on a GPIO pin, or may be used  
to generate Interrupt events.  
The temperature sensor can be configured to shut down the speaker outputs in the event of an  
overtemperature condition. This is configured using the THERR_ACT register field.  
PD, May 2011, Rev 4.1  
103  