WM8802  
Product Preview  
IEC61937, DTS-CD/LD DETECTION FLAG OUTPUT  
A function to output IEC61937 and DTS-CD/LD detection flags for non-PCM data is provided.  
When the UNPCM non-PCM signal output setting is selected, as well as an indication on the AUDIO  
pin, an interrupt signal is output from INT upon detection of an IEC61937 or DTS-CD/LD sync signal.  
Non-PCM signal details can be known by reading this information from the output register.  
The IEC61937 sync signal is detected and output when channel status bit 1 is non-PCM data ("1").  
The IEC61937 sync signal is not output if bit 1 is PCM data (“0”).  
DTS-CD/LD sync signal detection is done based on the sync pattern and the base frequency. In the  
case of DTS-ES data detection, output is performed when the DTS5.1 channel sync signal is  
detected and the DTS-ES sync pattern has been verified.  
The IEC61937 and DTS-CD/LD detection flags are cleared when fs has changed or upon occurrence  
of a PLL lock error or data error.  
Since the DTS sync signal is provided within the audio data, digital data with the same code as the  
DTS sync signal may in rare cases exist for regular CD/LD records that are not recorded in the DTS  
format. Protection using the sync pattern or base frequency is provided so that such data is not  
misinterpreted as DTS-CD/LD detection flags. The detection sequence is shown below.  
Input data  
NO  
Bit 1 detection  
Bit 1 = 1  
YES  
DTS-CD/LD  
SYNC  
detection  
NO  
NO  
PaPb  
detection  
YES  
YES  
Frame counter  
reset  
Frame counter  
start  
Frame counter  
start  
Frame counter  
reset  
PaPb  
detection  
during 4096  
frames  
Frame count  
512, 1024, 2048, 4096  
SYNC detection  
NO  
NO  
YES  
YES  
DTS-CD/LD flag  
not valid  
INT lowered  
IEC61937  
flag  
DTS-CD/LD flag OK  
INT lowered  
IEC61937 flag OK  
INT lowered  
*
Frame count hold  
x2 count detection  
expansion  
PaPb  
detection  
during 4096  
frames  
NO  
Depending on the frame count,  
the subsequent detection count  
is expanded up to x2.  
*
YES  
Frame count  
512, 1024, 2048, 4096  
SYNC detection  
NO  
*
IEC61937 data  
hold  
Periodic fluctuation is supported.  
1st count  
2nd count  
YES  
512 => 512 or 1024  
1024 => 1024 or 2048  
2048 => 2048 or 4096  
4096 => 4096  
DTS-CD/LD  
data hold  
Figure 24 Detection Flag Output Flowchart  