WM8580  
Production Data  
REGISTER  
ADDRESS  
BIT  
LABEL  
DEFAULT  
DESCRIPTION  
4
TXVAL_OVWR  
0
S/PDIF Transmitter Validity Overwrite Mode  
0 = disabled, validity bit is 0 when transmitter sources ADC,  
PAIF or SAIF, or is matches the S/PDIF input validity when  
S/PDIF transmitter sources S/PDIF receiver.  
1 = enabled, validity bit transmitted for subframe 0 is defined  
by TXVAL_SF0, validity bit transmitted for subframe 1 is  
defined by TXVAL_SF1.  
5
6
TXVAL_SF0  
TXVAL_SF1  
0
0
Overwrite Mode S/PDIF Transmitter Validity Sub-Frame 0  
0 = transmit validity = 0  
1 = transmit validity = 1  
Overwrite Mode S/PDIF Transmitter Validity Sub-Frame 1  
0 = transmit validity = 0  
1 = transmit validity = 1  
R31  
SPDTXCHAN 1  
1Fh  
0
1
CON/PRO  
AUDIO_N  
CPY_N  
0
0
0 = Consumer Mode  
1 = Professional Mode (not supported by WM8580)  
0 = S/PDIF transmitted data is audio PCM.  
1 = S/PDIF transmitted data is not audio PCM.  
0 = Transmitted data has copyright asserted.  
1 = Transmitted data has no copyright assertion.  
000 = Data from Audio interface has no pre-emphasis.  
001 = Data from Audio interface has pre-emphasis.  
010 = Reserved (Audio interface has pre-emphasis).  
011 = Reserved (Audio interface has pre-emphasis).  
All other modes are reserved and should not be used.  
00 = Only valid mode for consumer applications.  
2
0
5:3  
DEEMPH[2:0]  
000  
7:6  
7:0  
CHSTMODE  
[1:0]  
00  
R32  
SPDTXCHAN 2  
20h  
CATCODE  
[7:0]  
00000000  
Category Code. Refer to S/PDIF specification for details.  
00h indicates “general” mode  
R33  
3:0  
5:4  
SRCNUM  
[3:0]  
0000  
00  
Indicates S/PDIF source number.  
No definitions are attached to data.  
Channel Number for Subframe 1  
SPDTXCHAN 3  
21h  
CHNUM1[1:0]  
CHNUM1  
Channel Status Bits[21:20]  
00  
01  
10  
11  
0000 = Do not use channel number  
0001 = Send to Left Channel  
0010 = Send to Right Channel  
0000 = Do not use channel number  
7:6  
CHNUM2[1:0]  
00  
Channel Number for Subframe 2  
CHNUM2  
Channel Status Bits[23:22]  
00  
01  
10  
11  
0000 = Do not use channel number  
0001 = Send to Left Channel  
0010 = Send to Right Channel  
0000 = Do not use channel number  
R34  
SPDTXCHAN 4  
22h  
3:0  
5:4  
FREQ[3:0]  
0001  
11  
Sampling Frequency Indicated.  
Refer to S/PDIF specification IEC60958-3 for details.  
0001 = Sampling Frequency not indicated.  
Clock Accuracy of Transmitted clock.  
00 = Level II  
CLKACU[1:0]  
01 = Level I  
10 = Level III  
11 = Interface frame rate not matched to sampling frequency.  
PD Rev 4.3 August 2007  