ERROR HANDLING IN SOFTWARE MODE  
When the TRANS_ERR flag is asserted, it indicates that the recovered Rx S/PDIF sub-frame  
is corrupted. This corruption can due to a BI-Phase error, a parity error or a pre-amble  
error.When the INVALID flag is asserted, it indicates that the recovered Rx S/PDIF sub-frame  
has been marked as being invalid by the source of the S/PDIF data. Both TRANS_ERR and  
INVALID indicate an error.  
The S/PDIF receiver has two modes of handling for these errors, manual and automatic. The  
mechanism for each flag is similar. The mechanisms are described below.  
MANUAL ERROR HANDLING  
This manual handling of errored Rx S/PDIF data can be used when an application processor  
is being interrupted via the INT_N signal. Appropriate action should be taken by the  
application processor to handle the error condition  
If the TRANS_ERR and INVALID error flags are not masked using the MASK register, the  
recovered S/PDIF Rx data is passed to the digital audio interface and DAC1 or to the S/PDIF  
transmitter irrespective of the state of the flag and the data content of the recovered  
stream.(Also refer to note 1 below). In this case, the application processor will be interrupted  
via the INT_N signal.  
AUTOMATIC ERROR HANDLING  
This automatic handling of errored Rx S/PDIF data can be used when an application  
processor is not being interrupted via the INT_N signal leaving the WM8580 to handle the  
error condition.  
If the TRANS_ERR and INVALID error flags are masked using the MASK register, the  
WM8580 output data from the S/PDIF Rx interface depends on the setting of FILLMODE. If  
FILLMODE=1, then the incoming data (which is errored) is overwritten with 0’s. If  
FILLMODE=0, then the last valid data sample is repeatedly output.  
For the INVALID flag, the automatic error handling can be disabled if ALWAYSVALID =1. If  
ALWAYSVALID is set, then the recovered Rx S/PDIF data, which is marked as invalid, will be  
allowed to pass to the digital audio interface or to the S/PDIF transmitter. The data will not be  
modified in any way.  
Notes  
1. For the S/PDIF receiver to S/PDIF transmitter data path, only the INVALID flag will  
cause data to be overwritten, the TRANS_ERR flag is not used to overwrite data which  
is passed to the S/PDIF transmitter.  
REGISTER  
ADDRESS  
BIT  
LABEL  
DEFAULT  
DESCRIPTION  
Fill Mode Overwrite Configuration  
R38  
GP01  
26h  
8
FILLMODE  
0
Determines S/PDIF receiver action when TRANS_ERR or  
INVALID flag is masked and error condition sets the flag:  
0 = Data from S/PDIF receiver is overwritten with last valid  
data sample when flag is set.  
1 = Data from S/PDIF receiver is overwritten as all zeros  
when flag is set.  
8
ALWAYSVALID  
0
Automatic Error Handling Configuration for INVALID  
Flag  
R39  
GP02  
27h  
0 = INVALID flag automatic error handling enabled.  
1 = INVALID flag automatic error handling disabled.  
Table 65 S/PDIF Receiver Automatic Error Handling Configuration Registers  