WM8352
Production Data
REGISTER
ADDRESS
BIT
LABEL
DEFAULT
DESCRIPTION
Force DC-DC1 PWM mode
REFER TO
R248 (F8h)
DCDC1 Test
Controls
4
DC1_FORCE_PWM
0
0 = Normal DC-DC operation
1 = Force DC-DC PWM mode
Reset by state machine.
Register F8h DCDC1 Test Controls
REGISTER
ADDRESS
BIT
LABEL
DEFAULT
DESCRIPTION
REFER TO
REFER TO
REFER TO
R250 (FAh)
DCDC3 Test
Controls
4
DC3_FORCE_PWM
0
Force DC-DC3 PWM mode
0 = Normal DC-DC operation
1 = Force DC-DC PWM mode
Reset by state machine.
Register FAh DCDC3 Test Controls
REGISTER
ADDRESS
BIT
LABEL
DEFAULT
DESCRIPTION
R251 (FBh)
DCDC4 Test
Controls
4
DC4_FORCE_PWM
0
Force DC-DC4 PWM mode
0 = Normal DC-DC operation
1 = Force DC-DC PWM mode
Reset by state machine.
Register FBh DCDC4 Test Controls
REGISTER
ADDRESS
BIT
LABEL
DEFAULT
DESCRIPTION
R253 (FDh)
DCDC6 Test
Controls
4
DC6_FORCE_PWM
0
Force DC-DC6 PWM mode
0 = Normal DC-DC operation
1 = Force DC-DC PWM mode
Reset by state machine.
Register FDh DCDC6 Test Controls
PD, February 2011, Rev 4.4
322