WM8352
Production Data
REGISTER
ADDRESS
BIT
LABEL
DEFAULT
DESCRIPTION
REFER TO
R229 (E5h)
Supply
overrides/statu
s 2
15
OVCR_LS_OVRDE
0
Readback of the raw signal value.
Allow direct control of this signal's input to the
debounce logic when the
CONVERTER_OC_OVRDE bit is set to 1.
11
10
9
UNDV_LDO4_OVRDE
UNDV_LDO3_OVRDE
UNDV_LDO2_OVRDE
UNDV_LDO1_OVRDE
UNDV_DC6_OVRDE
UNDV_DC5_OVRDE
UNDV_DC4_OVRDE
UNDV_DC3_OVRDE
UNDV_DC2_OVRDE
UNDV_DC1_OVRDE
0
0
0
0
0
0
0
0
0
0
Readback of the raw signal value.
Allow direct control of this signal's input to the
debounce logic when the
CONVERTER_UV_OVRDE bit is set to 1.
Readback of the raw signal value.
Allow direct control of this signal's input to the
debounce logic when the
CONVERTER_UV_OVRDE bit is set to 1.
Readback of the raw signal value.
Allow direct control of this signal's input to the
debounce logic when the
CONVERTER_UV_OVRDE bit is set to 1.
8
Readback of the raw signal value.
Allow direct control of this signal's input to the
debounce logic when the
CONVERTER_UV_OVRDE bit is set to 1.
5
Readback of the raw signal value.
Allow direct control of this signal's input to the
debounce logic when the
CONVERTER_UV_OVRDE bit is set to 1.
4
Readback of the raw signal value.
Allow direct control of this signal's input to the
debounce logic when the
CONVERTER_UV_OVRDE bit is set to 1.
3
Readback of the raw signal value.
Allow direct control of this signal's input to the
debounce logic when the
CONVERTER_UV_OVRDE bit is set to 1.
2
Readback of the raw signal value.
Allow direct control of this signal's input to the
debounce logic when the
CONVERTER_UV_OVRDE bit is set to 1.
1
Readback of the raw signal value.
Allow direct control of this signal's input to the
debounce logic when the
CONVERTER_UV_OVRDE bit is set to 1.
0
Readback of the raw signal value.
Allow direct control of this signal's input to the
debounce logic when the
CONVERTER_UV_OVRDE bit is set to 1.
Register E5h Supply overrides/status 2
PD, February 2011, Rev 4.4
318