欢迎访问ic37.com |
会员登录 免费注册
发布采购

WM8352 参数 Datasheet PDF下载

WM8352图片预览
型号: WM8352
PDF下载: 下载PDF文件 查看货源
内容描述: 欧胜音频Plusa ? ¢立体声CODEC与电源管理 [Wolfson AudioPlus™ Stereo CODEC with Power Management]
分类和应用:
文件页数/大小: 336 页 / 2353 K
品牌: WOLFSON [ WOLFSON MICROELECTRONICS PLC ]
 浏览型号WM8352的Datasheet PDF文件第273页浏览型号WM8352的Datasheet PDF文件第274页浏览型号WM8352的Datasheet PDF文件第275页浏览型号WM8352的Datasheet PDF文件第276页浏览型号WM8352的Datasheet PDF文件第278页浏览型号WM8352的Datasheet PDF文件第279页浏览型号WM8352的Datasheet PDF文件第280页浏览型号WM8352的Datasheet PDF文件第281页  
Production Data  
WM8352  
REGISTER  
ADDRESS  
BIT  
LABEL  
DEFAULT  
DESCRIPTION  
AUXADC AUX3 input select  
REFER TO  
2
1
0
AUXADC_SEL3  
0
0 = Disable AUX3 measurement  
1 = Enable AUX3 measurement  
Reset by state machine.  
AUXADC_SEL2  
AUXADC_SEL1  
0
0
AUXADC AUX2 input select  
0 = Disable AUX2 measurement  
1 = Enable AUX2 measurement  
Reset by state machine.  
AUXADC AUX1 input select  
0 = Disable AUX1 measurement  
1 = Enable AUX1 measurement  
Reset by state machine.  
Register 90h Digitiser Control (1)  
REGISTER  
ADDRESS  
BIT  
LABEL  
DEFAULT  
DESCRIPTION  
REFER TO  
R145 (91h) 13:12 AUXADC_MASKMODE[1:0]  
Digitiser  
Control (2)  
00  
AUXADC MASK input control  
00 = MASK is ignored  
01 = When MASK is asserted, all AUXADC  
measurements are inhibited.  
10 = Reserved  
11 = MASK input initiates AUXADC  
measurements. AUXADC_POLL and  
AUXADC_CTC have no effect. MASK  
polarity is controlled by GPn_CFG.  
Reset by state machine.  
10:8  
AUXADC_CRATE[2:0]  
000  
AUXADC measurement frequency in  
Continuous mode  
000 = 1Hz  
001 = 4Hz  
010 = 8Hz  
011 = 16Hz  
100 = 32Hz  
101 = 64Hz  
110 = 128Hz  
111 = 256Hz  
Reset by state machine.  
2
1
AUXADC_CAL  
0
1
Configure AUX3 input to be the VREF  
supply for AUXADC calibration.  
0 = AUX3 input connected to AUX3 pin  
1 = AUX3 input connected to unbuffered  
VREF  
Reset by state machine.  
AUXADC_RBMODE  
Enable for AUXADC bandgap (VREF) buffer.  
0 = AUXADC REFBUF is only enabled  
during conversions that use the VREF as a  
reference  
1 = AUXADC REFBUF is always enabled  
when the AUXADC is enabled  
Reset by state machine.  
0
AUXADC_WAIT  
0
Whether the old data must be read before  
new conversions can be made  
0 = No effect (new conversions overwrite  
old)  
1 = New conversions are held back (and  
PD, February 2011, Rev 4.4  
277  
w
 复制成功!