 浏览型号WM8326GEFL/RV的Datasheet PDF文件第133页浏览型号WM8326GEFL/RV的Datasheet PDF文件第134页浏览型号WM8326GEFL/RV的Datasheet PDF文件第135页浏览型号WM8326GEFL/RV的Datasheet PDF文件第136页浏览型号WM8326GEFL/RV的Datasheet PDF文件第138页浏览型号WM8326GEFL/RV的Datasheet PDF文件第139页浏览型号WM8326GEFL/RV的Datasheet PDF文件第140页浏览型号WM8326GEFL/RV的Datasheet PDF文件第141页  
Production Data  
WM8326  
26 TEMPERATURE SENSING  
The WM8326 provides temperature monitoring as status information and also for self-protection of the  
device. Temperature monitoring is always enabled in the ON and SLEEP states.  
The thermal warning temperature can be set using the THW_TEMP register field. The thermal  
warning hysteresis ensures that the THW_TEMP is not reset until the device temperature has  
dropped below the threshold by a suitable margin. The extent of the hysteresis can be selected using  
the THW_HYST register field.  
The Thermal Warning condition can be read using the THW_STS register bit. An overtemperature  
condition causes the thermal warning interrupt (TEMP_THW_CINT) to be set. The thermal warning  
interrupt is also set when the overtemperature condition clears, ie. when the device has returned to its  
normal operating limits.  
The thermal shutdown temperature is set at a fixed level. If a thermal shutdown condition is detected  
whilst in the ON or SLEEP states, then a System Reset is triggered, as described in Section 24.1,  
forcing a transition to the OFF state.  
The temperature sensing circuit is configured and monitored using the register fields described in  
Table 81.  
ADDRESS  
BIT  
LABEL  
DEFAULT  
DESCRIPTION  
Thermal Warning hysteresis  
0 = 8 degrees C  
R16386  
(4002h)  
THW_HYST  
3
1
1 = 16 degrees C  
THW_TEMP  
[1:0]  
Thermal Warning temperature  
00 = 90 degrees C  
1:0  
15  
10  
01 = 100 degrees C  
10 = 110 degrees C  
11 = 120 degrees C  
R16397  
(400Dh)  
THW_STS  
Thermal Warning status  
0 = Normal  
0
1 = Overtemperature Warning  
(warning temperature is set by THW_TEMP)  
Table 81 Temperature Sensing Control  
The thermal warning interrupt event is indicated by the TEMP_THW_CINT register field. This  
secondary interrupt triggers a primary Thermal Interrupt, TEMP_INT (see Section 23). This can be  
masked by setting the mask bit as described in Table 82.  
ADDRESS  
R16401  
BIT  
LABEL  
DESCRIPTION  
Thermal Warning interrupt  
TEMP_THW_CINT  
1
(4011h)  
(Rising and Falling Edge triggered)  
Note: Cleared when a ‘1’ is written.  
Interrupt Status  
1
R16410  
(4019h)  
IM_TEMP_THW_CINT  
Interrupt mask.  
1
0 = Do not mask interrupt.  
1 = Mask interrupt.  
Interrupt Status  
1 Mask  
Default value is 1 (masked)  
Table 82 Thermal Interrupts  
PD, June 2012, Rev 4.0  
137  