 浏览型号WM8321GEFL/RV的Datasheet PDF文件第193页浏览型号WM8321GEFL/RV的Datasheet PDF文件第194页浏览型号WM8321GEFL/RV的Datasheet PDF文件第195页浏览型号WM8321GEFL/RV的Datasheet PDF文件第196页浏览型号WM8321GEFL/RV的Datasheet PDF文件第198页浏览型号WM8321GEFL/RV的Datasheet PDF文件第199页浏览型号WM8321GEFL/RV的Datasheet PDF文件第200页浏览型号WM8321GEFL/RV的Datasheet PDF文件第201页  
Production Data  
WM8321  
REGISTER  
ADDRESS  
BIT  
LABEL  
DEFAULT  
DESCRIPTION  
REFER TO  
66h to 7Fh = 3.4V  
DC3_ON_VSE  
L [1:0]  
DC-DC3 ON Voltage select  
1:0  
00  
DC3_ON_VSEL [6:0] selects the DC-DC3 output  
voltage from 0.85V to 3.4V in 25mV steps.  
See DC3_ON_VSEL [6:2] for definition.  
Register 4062h DC3 ON Config  
REGISTER  
ADDRESS  
BIT  
LABEL  
DEFAULT  
DESCRIPTION  
REFER TO  
R16483  
(4063h) DC3  
SLEEP  
DC3_SLP_SLO  
T [2:0]  
DC-DC3 SLEEP Slot select  
15:13  
000  
000 = SLEEP voltage / operating mode transition in  
Timeslot 5  
Control  
001 = Disable in Timeslot 5  
010 = Disable in Timeslot 4  
011 = Disable in Timeslot 3  
100 = Disable in Timeslot 2  
101 = Disable in Timeslot 1  
110 = SLEEP voltage / operating mode transition in  
Timeslot 3  
111 = SLEEP voltage / operating mode transition in  
Timeslot 1  
If DC-DC3 is assigned to a Hardware Enable Input,  
then codes 001-101 select in which timeslot the  
converter enters its SLEEP condition.  
DC3_SLP_MO  
DE [1:0]  
DC-DC3 SLEEP Operating Mode  
9:8  
6:0  
11  
00 = Forced Continuous Conduction Mode  
01 = Auto Mode (Continuous / Discontinuous  
Conduction with Pulse-Skipping)  
10 = LDO Mode  
11 = Hysteretic Mode  
DC3_SLP_VSE  
L [6:0]  
DC-DC3 SLEEP Voltage select  
0.85V to 3.4V in 25mV steps  
000_0000  
00h = 0.85V  
01h = 0.875V  
65h = 3.375V  
66h to 7Fh = 3.4V  
Register 4063h DC3 SLEEP Control  
REGISTER  
ADDRESS  
BIT  
LABEL  
DEFAULT  
DESCRIPTION  
REFER TO  
R16484  
(4064h) DC4  
Control 1  
DC4_SLV  
DC-DC4 Slave Mode select  
0 = Disabled  
13  
0
1 = Enabled  
DC4_SLV = 1, then DC-DC4 is a slave to DC-DC3, and  
both converters are controlled by the DC-DC3 registers.  
This field can only be written to by loading configuration  
settings from OTP/ICE. In all other cases, this field is  
Read Only.  