 浏览型号WM8321GEFL/RV的Datasheet PDF文件第112页浏览型号WM8321GEFL/RV的Datasheet PDF文件第113页浏览型号WM8321GEFL/RV的Datasheet PDF文件第114页浏览型号WM8321GEFL/RV的Datasheet PDF文件第115页浏览型号WM8321GEFL/RV的Datasheet PDF文件第117页浏览型号WM8321GEFL/RV的Datasheet PDF文件第118页浏览型号WM8321GEFL/RV的Datasheet PDF文件第119页浏览型号WM8321GEFL/RV的Datasheet PDF文件第120页  
WM8321  
Production Data  
22.2.2 POWER STATE STATUS  
Setting LEDn_SRC = 01 configures the associated LED to indicate Power State status. Under this  
selection, four different conditions may be indicated, as defined in Table 61.  
LED DRIVER  
DESCRIPTION  
Power Sequence Failure  
PVDD Low  
DRIVE MODE  
LED ‘ON’  
TIME  
ON:OFF  
DUTY CYCLE  
Pulsed sequence  
(4 pulses)  
1s  
1:1  
1:3  
n/a  
Continuous  
pulsed  
250ms  
n/a  
LED1 or  
LED2  
ON state  
Constant  
SLEEP state  
Continuous  
pulsed  
250ms  
1:7  
Table 61 System Status LED Outputs - Power State Status  
If more than one of the conditions listed occurs simultaneously, then the LED output pattern is  
controlled by the condition in the highest position within the list above.  
For example, if the PVDD Low condition occurs while in the ON or SLEEP states, then the LED  
output follows the pattern defined for the PVDD Low condition.  
The PVDD Low indication is asserted if PVDD is less than the user-selectable threshold  
SYSLO_THR, as described in Section 24.4.  
Note that, in the case of Power Sequence Failure, the transition to OFF occurs after the 4 LED pulses  
have been emitted.  
22.2.3 MANUAL MODE  
Setting LEDn_SRC = 11 configures the associated LED to operate in Manual Mode, which is  
configured using additional register fields.  
In Manual Mode, the LED output can be commanded as Off, On (Constant), Continuous Pulsed or  
Pulsed Sequence. The selected operation is determined by the LEDn_MODE registers as described  
in Table 62.  
In Continuous Pulsed mode and Pulsed Sequence mode, the ‘On’ time and the Duty Cycle can be  
configured using the LEDn_DUR and LEDn_DUTY_CYC registers respectively.  
In Pulsed Sequence mode, the number of pulses in the sequence can be selected using the  
LEDn_SEQ_LEN register. On completion of the commanded number of pulses, the LED remains off  
until LEDn_MODE or LEDn_SRC is changed to another value.  
ADDRESS  
R16460  
(404Ch)  
BIT  
LABEL  
DEFAULT  
DESCRIPTION  
LED1 Mode  
LED1_MODE  
[1:0]  
9:8  
00  
(Controls LED1 in Manual Mode  
only.)  
Status LED1  
00 = Off  
01 = Constant  
10 = Continuous Pulsed  
11 = Pulsed Sequence  
LED1 Pulse Sequence Length  
LED1_SEQ_LE  
N [1:0]  
5:4  
10  
(when LED1_MODE = Pulsed  
Sequence)  
00 = 1 pulse  
01 = 2 pulses  
10 = 4 pulses  
11 = 7 pulses  
PD, February 2012, Rev 4.0  
116  