W83627HF/ F/ HG/ G
Table 8-1 IRQSER Sampling periods
IRQ/DATA FRAME
SIGNAL SAMPLED
# OF CLOCKS PAST START
1
2
IRQ0
IRQ1
2
5
3
8
SMI
IRQ3
4
5
11
14
17
20
23
26
29
32
35
38
41
44
47
IRQ4
6
IRQ5
7
IRQ6
8
IRQ7
9
IRQ8
10
11
12
13
14
15
16
IRQ9
IRQ10
IRQ11
IRQ12
IRQ13
IRQ14
IRQ15
17
18
50
53
56
59
62
95
IOCHCK
INTA
19
INTB
20
INTC
21
INTD
32:22
Unassigned
8.3
Stop Frame
After all IRQ/Data Frames have completed, the host controller will terminate IRQSER by a Stop frame.
Only the host controller can initiate the Stop frame by driving IRQSER low for 2 or 3 clocks. If the Stop
Frame is low for 2 clocks, the next IRQSER cycle's Sample mode is the Quiet mode. If the Stop
Frame is low for 3 clocks, the next IRQSER cycle's Sample mode is the Continuous mode.
Publication Release Date: June 09, 2006
- 77 -
Revision 2.27