欢迎访问ic37.com |
会员登录 免费注册
发布采购

W83627HG-AW 参数 Datasheet PDF下载

W83627HG-AW图片预览
型号: W83627HG-AW
PDF下载: 下载PDF文件 查看货源
内容描述: WINBOND LPC I / O [Winbond LPC I/O]
分类和应用: PC时钟
文件页数/大小: 131 页 / 1020 K
品牌: WINBOND [ WINBOND ]
 浏览型号W83627HG-AW的Datasheet PDF文件第78页浏览型号W83627HG-AW的Datasheet PDF文件第79页浏览型号W83627HG-AW的Datasheet PDF文件第80页浏览型号W83627HG-AW的Datasheet PDF文件第81页浏览型号W83627HG-AW的Datasheet PDF文件第83页浏览型号W83627HG-AW的Datasheet PDF文件第84页浏览型号W83627HG-AW的Datasheet PDF文件第85页浏览型号W83627HG-AW的Datasheet PDF文件第86页  
W83627HF/ F/ HG/ G  
9. CONFIGURATION REGISTER  
9.1 Plug and Play Configuration  
The W83627HF/F uses Compatible PNP protocol to access configuration registers for setting up dif-  
ferent types of configurations. In W83627HF/F, there are eleven Logical Devicesfrom Logical De-  
vice 0 to Logical Device B with the exception of logical device 4 for backward compatibilitywhich  
correspond to eleven individual functionsFDClogical device 0, PRTlogical device 1,  
UART1 logical device 2, UART2logical device 3, KBClogical device 5, CIRConsumer  
IR, logical device 6, GPIO1logical device 7, GPIO2logical device 8, GPIO3logical device  
9, ACPI logical device A, and hardware monitor logical device B. Each Logical Device has  
its own configuration registers above CR30. Host can access those registers by writing an appro-  
priate logical device number into logical device select register at CR7.  
9.1.1 Compatible PnP  
9.1.1.1 Extended Function Registers  
In Compatible PnP, there are two ways to enter Extended Function and read or write the configuration  
registers. HEFRASCR26 bit 6can be used to select one out of these two methods of entering the  
Extended Function mode as follows:  
HEFRAS  
ADDRESS AND VALUE  
0
1
write 87h to the location 2Eh twice  
write 87h to the location 4Eh twice  
After Power-on reset, the value on RTSA pin 51is latched by HEFRAS of CR26. In Compatible  
PnP, a specific value87hmust be written twice to the Extended Functions Enable RegisterI/O  
port address 2Eh or 4Eh. Secondly, an index value 02h, 07h ~ FFhmust be written to the Ex-  
tended Functions Index RegisterI/O port address 2Eh or 4Eh same as Extended Functions Enable  
Registerto identify which configuration register is to be accessed. The designer can then access  
the desired configuration register through the Extended Functions Data RegisterI/O port address  
2Fh or 4Fh.  
After programming of the configuration register is finished, an additional valueAAhshould be writ-  
ten to EFERs to exit the Extended Function mode to prevent unintentional access to those configura-  
- 78 -  
 
 复制成功!