W83195WG-382/W83195CG-382
STEPLESS FOR ATI K8 CLOCK GENERATOR
5
WD_TIMEOUT
0
Read Back only. Timeout Flag.
1 : Watchdog has ever started and count to zero.
0 : a.) Watchdog is restarted and counting.
b.) Power on default state
R
4
3
2
1
0
SAF_FREQ<4>
SAF_FREQ<3>
SAF_FREQ<2>
SAF_FREQ<1>
SAF_FREQ<0>
0
0
0
1
0
These bits will be reloaded in Reg-0 to select
frequency table. As the watchdog is timeout and
EN_SAFE_FREQ=1.
R/W
7.7
BIT
Register 6: ( Default : FFh )
AFFECTED PIN/
FUNCTION NAME(S)
PWD
FUNCTION DESCRIPTION
TYPE
7
SRCEN<7>
1
SRC7 output control
1: Enable
0: Disable
SRC6 output control
1: Enable
0: Disable
SRC5 output control
1: Enable
0: Disable
SRC4 output control
1: Enable
0: Disable
SRC3 output control
1: Enable
0: Disable
ATIG1 output control
1: Enable
0: Disable
ATI clock can’t be controlled by CLKREQ# pins
ATIG0 output control
1: Enable
0: Disable
ATI clock can’t be controlled by CLKREQ# pins
SRC0 output control
1: Enable
0: Disable
R/W
6
SRCEN<6>
1
R/W
5
SRCEN<5>
1
R/W
4
SRCEN<4>
1
R/W
3
SRCEN<3>
1
R/W
2
ATIGEN<1>
1
R/W
1
ATIGEN<0>
1
R/W
0
SRCEN<0>
1
R/W
-9-
Publication Release Date: Feb 2006