W25Q128BV  
7.1.6 Complement Protect Bit (CMP)  
The Complement Protect bit (CMP) is a non-volatile read/write bit in the status register (S14). It is used in  
conjunction with SEC, TB, BP2, BP1 and BP0 bits to provide more flexibility for the array protection. Once  
CMP is set to 1, previous array protection set by SEC, TB, BP2, BP1 and BP0 will be reversed. For  
instance, when CMP=0, a top 4KB sector can be protected while the rest of the array is not; when CMP=1,  
the top 4KB sector will become unprotected while the rest of the array become read-only. Please refer to  
the Status Register Memory Protection table for details. The default setting is CMP=0.  
7.1.7 Status Register Protect Bits (SRP1, SRP0)  
The Status Register Protect bits (SRP1 and SRP0) are non-volatile read/write bits in the status register  
(S8 and S7). The SRP bits control the method of write protection: software protection, hardware  
protection, power supply lock-down or one time programmable (OTP) protection.  
Status  
Register  
SRP1 SRP0 /WP  
Description  
Software  
Protection  
/WP pin has no control. The Status register can be written to  
after a Write Enable instruction, WEL=1. [Factory Default]  
0
0
0
1
0
1
1
0
1
X
0
Hardware  
Protected  
When /WP pin is low the Status Register locked and can not  
be written to.  
Hardware  
Unprotected  
When /WP pin is high the Status register is unlocked and can  
be written to after a Write Enable instruction, WEL=1.  
1
Power Supply Status Register is protected and can not be written to again  
Lock-Down  
X
X
until the next power-down, power-up cycle.(1)  
One Time  
Program(2)  
Status Register is permanently protected and can not be  
written to.  
1
Note:  
1. When SRP1, SRP0 = (1, 0), a power-down, power-up cycle will change SRP1, SRP0 to (0, 0) state.  
2. This feature is available upon special order. Please contact Winbond for details.  
7.1.8 Erase/Program Suspend Status (SUS)  
The Suspend Status bit is a read only bit in the status register (S15) that is set to 1 after executing an  
Erase/Program Suspend (75h) instruction. The SUS status bit is cleared to 0 by Erase/Program Resume  
(7Ah) instruction as well as a power-down, power-up cycle.  
7.1.9 Security Register Lock Bits (LB3, LB2, LB1)  
The Security Register Lock Bits (LB3, LB2, LB1) are non-volatile One Time Program (OTP) bits in Status  
Register (S13, S12, S11) that provide the write protect control and status to the Security Registers. The  
default state of LB[3:1] is 0, Security Registers are unlocked. LB[3:1] can be set to 1 individually using the  
Write Status Register instruction. LB[3:1] are One Time Programmable (OTP), once it’s set to 1, the  
corresponding 256-Byte Security Register will become read-only permanently.  
- 14 -  
 