W25M02GV  
7.2 Configuration Register / Status Register-2 (Volatile Writable)  
Figure 3b. Configuration Register / Status Register-2 (Address Bxh)  
7.2.1  
One Time Program Lock Bit (OTP-L) – OTP lockable  
In addition to the main memory array, W25M02GV also provides an OTP area for the system to store  
critical data that cannot be changed once it’s locked. The OTP area consists of 10 pages of 2,112-Byte  
each. The default data in the OTP area are FFh. Only Program command can be issued to the OTP area  
to change the data from “1” to “0”, and data is not reversible (“0” to “1”) by the Erase command. Once the  
correct data is programmed in and verified, the system developer can set OTP-L bit to 1, so that the entire  
OTP area will be locked to prevent further alteration to the data.  
7.2.2 Enter OTP Access Mode Bit (OTP-E) – Volatile Writable  
The OTP-E bit must be set to 1 in order to use the standard Program/Read commands to access the OTP  
area as well as to read the Unique ID / Parameter Page information. The default value after power up or a  
RESET command is 0.  
7.2.3 Status Register-1 Lock Bit (SR1-L) – OTP lockable  
The SR1-L lock bit is used to OTP lock the values in the Protection Register (SR-1). Depending on the  
settings in the SR-1, the device can be configured to have a portion of or up to the entire array to be write-  
protected, and the setting can be OTP locked by setting SR1-L bit to 1. SR1-L bit can only be set to 1  
permanently when SRP1 & SRP0 are set to (1,1), and OTP Access Mode must be entered (OTP-E=1) to  
execute the programming. Please refer to 8.2.26 for detailed information.  