SCA61T Series  
Temperature dependency of SCA61T sensitivity  
1.0  
0.5  
specification  
limit  
0.0  
-0.5  
-1.0  
-1.5  
-2.0  
-2.5  
average  
+3 sigma  
-3 sigma  
specification  
limit  
-40  
-20  
0
20  
40  
60  
80  
100  
120  
Temp [°C]  
Figure 5.  
Typical temperature dependency of SCA61T sensitivity  
1.9 Additional External Compensation  
To achieve the best possible accuracy, the temperature measurement information and typical  
temperature dependency curves can be used for SCA61T offset and sensitivity temperature  
dependency compensation. The equation for the fitted 3rd order polynome curve for offset  
compensation is:  
Offcorr = −0.0000005*T 3 + 0.0000857*T 2 0.0032*T + 0.0514  
Where:  
Offcorr:  
T
3rd order polynome fitted to average offset temperature dependency curve  
temperature in °C (Refer to paragraph 2.7 Temperature Measurement)  
The calculated compensation curve can be used to compensate for the temperature dependency  
of the SCA61T offset by using the following equation:  
OFFSETcomp = Offset Offcorr  
Where:  
OFFSETcomp  
Offset  
temperature compensated offset in degrees  
Nominal offset in degrees  
The equation for the fitted 2nd order polynome curve for sensitivity compensation is:  
Scorr = −0.00011*T 2 + 0.0019*T + 0.0362  
Where:  
Scorr:  
T
2nd order polynome fitted to average sensitivity temperature dependency curve  
temperature in °C  
The calculated compensation curve can be used to compensate the temperature dependency of  
the SCA61T sensitivity by using the following equation:  
SENScomp = SENS *(1+ Scorr /100)  
Where:  
SENScomp temperature compensated sensitivity  
SENS  
Nominal sensitivity (4V/g SCA61T-FAHH1G, 2V/g SCA61T-FA1H1G)  
The typical offset and sensitivity temperature dependency after external compensation is shown in  
the following diagrams.  
VTI Technologies Oy  
www.vti.fi  
Subject to changes  
Doc. nr. 8261900  
7/18  
Rev.A  