 浏览型号CMA3000-D01DEMO的Datasheet PDF文件第26页浏览型号CMA3000-D01DEMO的Datasheet PDF文件第27页浏览型号CMA3000-D01DEMO的Datasheet PDF文件第28页浏览型号CMA3000-D01DEMO的Datasheet PDF文件第29页浏览型号CMA3000-D01DEMO的Datasheet PDF文件第31页浏览型号CMA3000-D01DEMO的Datasheet PDF文件第32页浏览型号CMA3000-D01DEMO的Datasheet PDF文件第33页浏览型号CMA3000-D01DEMO的Datasheet PDF文件第34页  
CMA3000-D0X Series  
Equation 10  
2
SZX 2 + SZY  
CrossZ = ±  
100%,  
SZ  
where SZX is Z-axis sensitivity to X-axis acceleration [Count/g], SZY is Z-axis sensitivity to Y-axis  
acceleration [Count/g] and SZ is sensitivity of Z-axis [Count/g].  
Cross-axis sensitivity of CMA3000 family is measured in centrifuge over specified measurement  
range during qualification. Correct mounting position of component is important during the  
measurement of cross-axis sensitivity.  
8.7 Turn-on time  
Turn-on time is the time when the last of one X, Y, Z axis output readings stabilizes into its final  
value after XRESET is pulled high. The final value limits in turn-on time measurements is defined to  
be ±1 % of the sensor’s full scale measuring range (for example for CMA3000-D01 ±2g →  
FS = 2 g). Turn-on time definition for Z-axis is presented in Figure 23 below.  
Acceleration  
Supply voltage reaches the  
minimum required level  
CMA3000 starts  
CMA3000 output  
inside ±1% FS  
limits  
CMA3000  
Z-axis output  
Time scale  
Turn on time  
Figure 23. Turn-on time definition for one axis.  