DG540/541/542
Vishay Siliconix
SPECIFICATIONS
a
Test Conditions
Unless Specified
Parameter
Analog Switch
Analog Signal Range
Drain-Source
On-Resistance
r
DS(on)
Match
Source Off
Leakage Current
Drain Off
Leakage Current
Channel On
Leakage Current
V
ANALOG
r
DS(on)
Dr
DS(on)
I
S(off)
I
D(off)
I
D(on)
V
S
= 0 V, V
D
= 10 V
V
S
= 10 V, V
D
= 0 V
V
S
= V
D
= 0 V
V– = –5 V, V+ = 12 V
Full
Room
Full
Room
Room
Full
Room
Full
Room
Full
30
2
–0.05
–0.05
–0.05
–10
–500
–10
–500
–10
–1000
–5
5
60
100
6
10
500
10
500
10
1000
–10
–100
–10
–100
–10
–100
–5
5
60
75
6
10
100
10
100
10
100
nA
A
V
W
A Suffix
–55 to 125_C
D Suffixes
–40 to 85_C
Symbol
V+ = 15 V, V– = –3 V
V
INH
= 2 V, V
INL
= 0.8 V
f
Temp
b
Typ
c
Min
d
Max
d
Min
d
Max
d
Unit
I
S
= –10 mA, V
D
= 0 V
,
Digital Control
Input Voltage High
Input Voltage Low
Input Current
V
INH
V
INL
I
IN
V
IN
= GND or V+
Full
Full
Room
Full
0.05
–1
–20
2
0.8
1
20
–1
–20
2
V
0.8
1
20
mA
Dynamic Characteristics
On State Input Capacitance
e
Off State Input Capacitance
e
Off State Output Capacitance
e
Bandwidth
C
S(on)
C
S(off)
C
D(off)
BW
V
S
= V
D
= 0 V
V
S
= 0 V
V
D
= 0 V
R
L
= 50
W
, See Figure 5
DG540
DG541
Turn On Time
t
ON
R
L
= 1 kW
C
L
= 35 p
pF
50% t 90%
to
See Figure 2
Turn Off Time
t
OFF
DG542
Charge Injection
Q
C
L
= 1000 pF, V
S
= 0 V
See Figure 3
R
IN
= 75
W
R
L
= 75
W
f = 5 MHz
See Figure 4
R
IN
= 10
W
, R
L
= 75
W
f = 5 MHz, See Figure 6
DG540
DG541
DG542
DG542
DG540
DG541
Room
Room
Room
Room
Room
Full
Room
Full
Room
Full
Room
Full
Room
Room
Room
Room
Room
14
2
2
500
45
55
20
25
70
130
100
160
50
85
60
85
70
130
100
160
ns
50
85
60
85
pC
20
4
4
20
4
4
MHz
pF
F
–25
–80
–60
–75
–85
Isolation
Off I l i
OIRR
dB
All Hostile Crosstalk
X
TALK(AH)
Power Supplies
Positive Supply Current
Negative Supply Current
I+
All Channels On or Off
I–
Room
Full
–3.2
–6
–9
–6
–9
Room
Full
3.5
6
9
6
9
mA
Notes:
a. Refer to PROCESS OPTION FLOWCHART.
b. Room = 25_C, Full = as determined by the operating temperature suffix.
c. Typical values are for DESIGN AID ONLY, not guaranteed nor subject to production testing.
d. The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this data sheet.
e. Guaranteed by design, not subject to production test.
f.
V
IN
= input voltage to perform proper function.
www.vishay.com
S
FaxBack 408-970-5600
Document Number: 70055
S-00399—Rev. G, 13-Sep-99
4-4