10-FU073AA030SM-PF04H06
datasheet
Negative Neutral Point Switching Characteristics
figure 37.
FWD
figure 38.
FWD
Typical rate of fall of forward and reverse recovery current as a function of collector current
Typical rate of fall of forward and reverse recovery current as a function of turn on gate resistor
diF/dt, dirr/dt = f(IC)
diF/dt, dirr/dt = f(Rgon)
2000
3500
3000
2500
2000
1500
1000
500
diF/dt ‒ ‒ ‒ ‒ ‒
diF/dt ‒ ‒ ‒ ‒ ‒
dirr/dt ──────
1750
1500
1250
1000
750
500
250
0
dirr/dt ──────
0
0
10
20
30
40
50
60
0
10
20
30
40
50
60
70
IC(A)
Rgon(Ω)
With an inductive load at
With an inductive load at
25 °C
25 °C
VCE
VGE
Rgon
=
=
=
VCE
VGE
IC
=
=
=
400
0/15
16
V
V
Ω
125 °C
150 °C
400
0/15
30
V
V
A
125 °C
150 °C
Tj:
Tj:
figure 39.
IGBT
Reverse bias safe operating area
IC = f(VCE
)
70
IC MAX
60
50
40
30
20
10
0
0
100
200
300
400
500
600
700
800
V
CE(V)
Tj =
At
150
°C
Rgon
Rgoff
=
=
16
16
Ω
Ω
Copyright Vincotech
24